Preliminar y, Programming and control, cont’d – Extron Electronics System 5 IP Series User Guide User Manual

Page 88

Advertising
background image

SIS

Programming and Control, cont’d

System 5 IP • SIS

Programming and Control

5-32

PRELIMINAR

Y

The syntax for setting a special function for a System 5 IP switcher is

X?

* __ # where

X?

is the value and

__ is the function number. To view a function’s setting, use __#, where __ is the function number. In the
following table the values of the

X?

variable are different for each command/function. These values are

given in the rightmost column. Special function commands are accessible only through RS-232.

Command/response table for special function SIS commands

Command

ASCII Command Response

X?

values

(host to System 5)

(System 5 IP to host)

and additional descriptions

Delay times

Most projectors require a certain amount of time during warm-up and cool-down during which they do not accept
commands. You can specify the amount of time for the System 5 IP to wait between sending the projector a power-on or
power-off command and when the next action can occur or the next command can be issued.

Power on delay

24

X?

*1 #

WarmUp*

X?

0 = 0 seconds,
1 = 2 seconds,
2 = 4 seconds,
... in 2 second steps up to
150 = 300 seconds (5 minutes).

Example:

8*1#

WarmUp*008

Example: set a 16 second power
on delay.

Example:

1#

WarmUp*023

Example:

view the power on delay

setting.

Power off delay

24

X?

*2 #

CoolDown*

X?

0 = 0 seconds,
1 = 2 seconds,
2 = 4 seconds,... in 2 second
steps up to 150 = 300 seconds.

Example:

23*2#

CoolDown*023

Example:

set a 46 second power off

delay.

Set the RGB delay

(Triple-Action Switching)

24

X?

*3 #

RGBDly*

X?

0 = 0.0 seconds (default), 1 = 0.5
seconds, 2 = 1.0 seconds,
... in ½ second steps up to
10 = 5.0 seconds.

Example:

7*3#

RGBDly*07

Example: 3.5 second RGB delay.

This command applies to RGB inputs only.

Set the Power Off button delay

24

X?

*48#

PwrOffDly*

X?

0 = the Power Off button
requires no hold delay to issue
power-down commands.
1 = the Power Off button
requires a 2 second hold delay
before the power-down
sequence starts.

Audio settings

Limit audio level on display power-on

24

X?

*11 #

VolLimit*

X?

If this feature is enabled, the
maximum initial power-up volume
level will not exceed the level
specified by this command.
0 = audio off, ...,
20 = default value (50% of max.
level), ...,
40 = no limit on audio level.

Example:

28*11#

VolLimit*028

Example: limit power-up volume
to 70% of maximum volume.

Set the audio output mode

X?

*18 #

AudioMode*

X?

Set the Preamp and amplified
outputs to be either mono or
stereo signals.
1 = mono
2 = stereo (default).