Programming and Control, cont’d

System 5 IP • SIS

Programming and Control

5-38

PRELIMINAR

Y

Command/response table for special function SIS commands, continued

Command

ASCII Command Response

X?

values

(host to MLC)

(MLC to host)

and additional descriptions

Input switching lockouts

Lock out input switching during power on/off

24

X?

* 53 #

PrwLock*

X?

This command prevents input
switching during display warm
up and cool down sequences.
For

X?

,

0 = off/disabled (default)
1 = on/enabled.

Input switching lockout duration

24

X?

* 54 #

IODelay*

X?

Use this command to prevent
input switching for a specific
period after an input has been
switched.

X?

= the lockout period

(0 - 65535 ms in 20 ms steps).

Switching lockout applies only to input buttons.

PINs (personal identification numbers)

Use personal identification numbers (PINs) to allow different types of access to switcher controls. These PINs can be
enabled only during times when the projector or display is powered off.

Enable PINs

24

X?

* 60 #

PINEnable*

X?

For

X?

,

0 = all levels (administrator and
user PINs) are enabled
1 = the administrator PIN is
enabled
2 = PIN-based access is disabled
for all levels (default).

Set a PIN

24

X?

*

Y?

* 61 #

PINNum

X?

*

Y?

This command allows you to set
a PIN for each level of access.
For

X?

,

0 = administrator level
1 = user level.

Y?

= any 4-digit combination of

the numbers 1, 2, 3, 4, and 5.
Default

Y?

values are as

follows:
• administrator = 1524
• user = 0.

Read/display the PIN

24

X?

* 61 #

Y?

For

X?

,

0 = administrator level
1 = user level.

Y?

= the 4-digit PIN.