1 programming example: preset value, 1 set encoder preset value – BEI Sensors THK4 User Manual

Page 16

Advertising
background image

www.beisensors.com

page

16/57

5.1 Programming example: Preset Value

If a CANopen device is connected and configured with the right baudrate and also configured to a unused

node number, it will start up into the pre-operational mode and send a bootup massage to the master.

5.1.1 Set Encoder Preset Value

Master to Encoder with Node Number 1

Setting Preset Value (Value 1000)

Identifier

DLC

Command

Index

Subindex Service/Process data

NN 1

Download

6003h

Byte 4 Byte 5 Byte 6 Byte 7

601

8

22

03

60

00

00

10

00

00

Answer of the Encoder

Identifier

DLC

Command

Index

Subindex Service/Process data

NN 1

Download

6003h

Byte 4 Byte 5 Byte 6 Byte 7

581

8

43

03

60

00

00

00

00

00

Read Preset Value from the Encoder

Identifier

DLC

Command

Index

Subindex Service/Process data

NN 1

Download

6003h

Byte 4 Byte 5 Byte 6 Byte 7

601

8

40

03

60

00

00

00

00

00

Answer of the Encoder

Identifier

DLC

Command

Index

Subindex Service/Process data

NN 1

Download

6003h

Byte 4 Byte 5 Byte 6 Byte 7

581

8

43

03

60

00

00

10

00

00

Save Preset Values

Identifier

DLC

Command

Index

Subindex Service/Process data

NN 1

Download

1010h

Byte 4 Byte 5 Byte 6 Byte 7

601

8

22

10

10

01

73

61

76

65

Advertising
This manual is related to the following products: