Object 1011h: restore parameters, Object 1012h: cob-id time stamp object, Object 1013h: high resolution time stamp – BEI Sensors THK4 User Manual

Page 23

Advertising
background image

www.beisensors.com

page

23/57

Object 1011h: Restore Parameters

This object is used to restore device and CANopen related parameters to factory settings.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0

Number of sub indices

Unsigned 8

2

ro

no

1

Restore all parameters

Unsigned 32

“load”

rw

no

Storing procedure

To save the parameters to non volatile memory the access signature “load” has to be sent to the

corresponding subindex of the device.

Most significant word Least significant word

ASCII D a

o

l

Hex value 64h

61h

6Fh

6Ch

Note: The restoration of parameters will only be taken into account after a power up or reset command.

Please check all parameters before you store them to the non volatile memory.

Object 1012h: COB-ID Time Stamp Object

This object contains the COB-ID of the Time Stamp object.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0 -

Unsigned

32

100h

rw

no

Object 1013h: High Resolution Time Stamp

This object contains a time stamp with a resolution of 1µs.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0 -

Unsigned

32

0

rw

no