Object 1014h: cob-id emergency object, Object 1016h: consumer heartbeat time, Object 1017h: producer heartbeat time – BEI Sensors THK4 User Manual

Page 24

Advertising
background image

www.beisensors.com

page

24/57

Object 1014h: COB-ID Emergency Object

This object contains the EMCY emergency message identifier.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0

-

Unsigned 32

80h + Node ID

rw

no

Object 1016h: Consumer Heartbeat Time

The consumer heartbeat time defines the expected heartbeat cycle time in ms. The device can only

monitor one corresponding device. If the time is set to 0 the monitoring is not active. The value of this

object must be higher than the corresponding time (object 1017) of the monitored device.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0

Number of indices

Unsigned 8

1

ro

no

1

Consumer heartbeat time

Unsigned 32

0

rw

yes

The context of subindex 1 is as follows:

Bit

31 to 24

23 to 16

15 to 0

Value

0h (reserved)

Address of monitored

device

Monitoring time (ms

Object 1017h: Producer Heartbeat Time

The object contains the time intervall in milliseconds in which the device has to produce the a heartbeat

message.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0 -

Unsigned

16

0

rw

yes