Object 1001h: error register, Object 1003h: pre-defined error field – BEI Sensors THK4 User Manual

Page 20

Advertising
background image

www.beisensors.com

page

20/57

Object 1001h: Error Register

This object is used by the device to display internal faults. When a fault is detected, the corresponding bit

is therefore activated.

The following errors are supported:

Bit

Description

Comments

0

Generic Error

The generic error is signaled at any error situation.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0 -

Unsigned

8

N/A

ro

no

Object 1003h: Pre-Defined Error Field

The object holds the errors that have occurred on the device and have been signaled via the Emergency

Object.

The error code is located in the least significant word

Additional Information is located in the most significant word

Subindex 0 contains the number of recorded errors

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0

Number of recorded errors

Unsigned 8

0

rw

no

1

Most recent errors

Unsigned 32

-

ro

no

2

Second to last error

Unsigned 32

-

ro

no

10

Clearing Error Log

The error log can be cleared by writing 0 to subindex 0 of object 1003.