If the desired resolution per revolution is less than the really physical resolution per revolution of the

encoder, then the total resolution must be entered as follows:

Total resolution:

Calculation example:

Customer handicap: AU = 2048

Encoder type sign:

PGA=24 bit, PAU=12bit

If the total resolution of the encoder is less than the physical total resolution, the parameter total resolution

must be a multiple of the physical total resolution:

Object 2103h: Preset Value

The preset value is the desired position value, which should be reached at a certain physical position of

the axis. The position value is set to the desired process value by the parameter preset. The preset value

must not exceed the parameter total resolution to avoid run-time errors. If the parameter value exceeds the

total resolution of the encoder a SDO “Out of range” message is generated.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0

Preset Value

Unsigned 32

0

rw

yes

Object 2104h: Limit Switch, min.

Two position values can be programmed as limit switches. By reaching this value, one bit of the 32 bit

process value is set to high. Both programmed values must not exceed the parameter total resolution to

avoid run-time errors. If the parameter value exceeds the total resolution of the encoder a SDO “Out of

range” message is generated.

Bit 30 = 1:

Limit Switch, Min. reached or passed under

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0

Limit Switch, min.

Unsigned 32

0

rw

yes

16777216 2048

4096

8388608

GA

GA