The limit switch, Min sets Bit 30=1 with the next message telegram, if the process value reaches or passes

under the value of the limit switch:

Function

Status

bits

Process value

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

0 1 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

Object 2105h: Limit Switch, max.

Two position values can be programmed as limit switches. By reaching this value, one bit of the 32 bit

process value is set to high. Both programmed values must not exceed the parameter total resolution to

avoid run-time errors. If the parameter value exceeds the total resolution of the encoder a SDO “Out of

range” message is generated.

Bit 31 = 1:

Limit Switch, Max. reached or passed beyond

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0

Limit Switch, max.

Unsigned 32

0

rw

yes

The limit switch, max sets Bit 31=1 with the next message telegram, if the process value reaches or

passes under the value of the limit switch:

Function

Status

bits

Process value

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

1 0 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

Object 2160h: Customer storage

This object provides for the customer the possibility to store any value.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0h

Number of sub indices

Unsigned 8

4h

ro

1h

Customer Storage1

Unsigned 32

rw