Object 100Ch: Guard Time

This object contains the guard time in milliseconds.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0 -

Unsigned

16

0

rw

yes

Object 100Dh: Life Time Factor

This object contains the life time factor parameters. The life time factor multiplied with the guard time gives

the life time for the node guarding protocol.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0 -

Unsigned

8

0

rw

yes

Object 1010h: Store Parameters

This object is used to store device and CANopen related parameters to non volatile memory.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0

Number of sub indices

Unsigned 8

2

ro

no

1

Store all parameters

Unsigned 32

“save”

rw

no

Storing procedure

To save the parameters to non volatile memory the access signature “save” has to be sent to the

corresponding subindex of the device.