Object 6504h: supported alarms, Object 6505h: warnings – BEI Sensors THK4 User Manual

Page 45

Advertising
background image

www.beisensors.com

page

45/57

Object 6504h: Supported alarms

The object shall provide the supported alarms of the device. Please refer to the bit structure table to find

more details about the supported alarms.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0h

Supported Alarms

Unsigned 16

1000h

ro

no

The CA-encoder supports the position error alarm.

Object 6505h: Warnings

This object shall provide the warnings. Warnings indicate that tolerance for certain internal parameters of

the encoder have been exceeded. In contrast to alarm and emergency messages warnings do not imply

incorrect position values. All warnings shall be cleared if the tolerances are again within normal

parameters.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0h Warnings

Unsigned

16

-

romap

no

Bit structure of the warnings

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Use

MS

MS

MS

MS

R R R R R R RP

BC

OT

CP

LC FE

Table Description:

MS:

Manufacturer Specific Warnings (not supported)

R:

Reserved for future use

RP:

Reference Point reached/not reached (not supported)

BC:

Battery charge (not supported)

OT:

Operating Time limit (not supported)

CP:

CPU watchdog status (not supported)

LC:

Light control reserve (not supported)

FE:

Frequency warning (not supported)

Advertising