Setting Node Number via SDO Objects

The node number has to be adjusted via SDO

objects. The default node number is 32. To set

the node number, object 3000h has to be

written. For further information regard

chapter 5.5 Object Dictionary.

Setting Baud Rate via SDO Objects

The baud rate has to be adjusted via SDO

objects. The default baud rate is 20 kBaud. To

set baud rate object 3001h has to be written. For

further information please regard chapter 5.5

Object Dictionary.

Setting Node Number via LSS

The node number can also be adjusted via

Layer Setting Services (LSS). For further

information regard chapter 4.5

Setting Baud Rate via LSS

The baud rate can also be adjusted via Layer

Setting Services (LSS). The default baud rate is

20 kBaud. For further information regard chapter

4.5.

Bus Termination

If the encoder is the last device in the bus you

can use an external termination resistor on a T-

coupler.