Flowline LU78 EchoSwitch User Manual

Page 24

Advertising
background image

24 of 34 

MN300282 

Rev A 

ELECTRICAL (cont.) 

Step Six 

Analog Output (4/20 mA):  The analog output of the EchoSwitch® is a sinking 4/20 mA control circuit.   The 
typical way to use this feature is to connect a positive supply to the MA+ input and to sense the current flow 
out of the MA‐ output with a sampling resistor as shown in the following diagram. 

 

The cabling should be a shielded twisted pair to minimize EMI interference.  Typically 20 to 24 gauge wire is 
used in this application.   The analog output of the EchoSwitch® is isolated from the AC power via optocoupler 
isolation.   

Note – 95 to 250 VAC power is required to provide power to the EchoSwitch® for basic operation.    

 

 

 