Flowline LU78 EchoSwitch User Manual

Page 4

Advertising
background image

4 of 34 

MN300282 

Rev A 

SAFETY PRECAUTIONS 

Step Three 

About this Manual: PLEASE READ THE ENTIRE MANUAL PRIOR TO INSTALLING OR USING THIS PRODUCT.  

This  manual  includes  information  on  the  EchoSwitch®  series  ultrasonic  level  switch  and  transmitter  from 
FLOWLINE.  Please  refer  to  the  part  number  located  on  the  switch  label  to  verify  the  exact  model 
configuration, which you have purchased.   

User’s  Responsibility  for  Safety:    FLOWLINE  manufactures  a  broad  range  of  level  sensing  technologies. 

While  each  of  these  sensors  is  designed  to  operate  in  a  wide  variety  of  applications,  it  is  the  user’s 
responsibility to select a sensor model that is appropriate for the application, install it properly, perform tests 
of the installed system, and maintain all components. The failure to do so could result in property damage or 
serious injury.  

Proper  Installation  and  Handling:    Only  properly  trained  staff  should  install  and/or  repair  this  product.  

Install the switch with the included Viton® gasket and never over tighten the switch within the fitting.  Always 
check for leaks prior to system start‐up. 

Wiring and Electrical:  A supply voltage of 95‐250 VAC is used to power the EchoSwitch®.  Electrical wiring 

of the switch should be performed in accordance with all applicable national, state, and local codes.  

Material  Compatibility:    The  enclosure  is  made  of  Polycarbonate  (PC).    The  transducer  is  made  of 

Polyvinylidene Fluoride (PVDF).  Make sure that the model, which you have selected, is chemically compatible 
with the application media.   

Enclosure:  While the switch housing is liquid‐resistant the EchoSwitch® is not designed to be operational 

when  immersed.    It  should  be  mounted  in  such  a  way  that  the  enclosure  and  transducer  do  not  come  into 
contact with the application media under normal operational conditions.   

The  enclosure  has  a  flip  cover  with  dual  1/2”  NPT  female  conduit  ports  and  an  internal  terminal  strip  for 
wiring.  To open the enclosure, you will need a small insertion tool such as a screwdriver.  Loosen the locking 
screw located at the top front of the enclosure.  Rotate the hinged cover up for 135° access to the faceplate 
and terminal strips. Before closing the enclosure, make sure that the enclosure gasket is properly seated, and 
that any conduit fittings, cable connectors or plugs are installed correctly and sealed. 

Handling Static‐Sensitive Circuits/Devices:  When handling the transmitter, the technician should follow 

these  guidelines  to  reduce  any  possible  electrostatic  charge  build‐up  on  the  technician’s  body  and  the 
electronic part. 

1. Always  touch  a  known  good  ground  source  before  handling  the  part.  This  should  be  repeated  while 

handling the part and more frequently after sitting down from a standing position, sliding across the 
seat or walking a distance. 

2. Avoid touching electrical terminals of the part unless making connections. 

3. DO NOT open the unit cover until it is time to calibrate. 

4. Wipe unit with a damp cloth when cleaning. 

 
 

 