Flowline LU78 EchoSwitch User Manual

Page 28

Advertising
background image

28 of 34 

MN300282 

Rev A 

INSTALLATION (cont.) 

Step Seven 

3. Flange (LU77 Series):  If installing on a flange, select a flange with a thread that is above the plane of 

the flange, such as the LM52‐1850.   

a. The LU74 & LU78 series works well with Flange installations. 
b. Avoid the use of blind flanges with tapped threads or flanges where the threads are even with 

the plane of the flange, such as the Banjo 1" Poly ANSI Flange (series AF100).  

c. Use a flange with a 2” thread and add a 2” to 1” reducer bushing to complete the installation. 

2” Flange w/ 

thread out of plane 

2” Flange w/ 

thread in plane 

2” Flange w/ 

Reducer Bushing 

 

 

Do not use thread in plane 

 

 

4. Side  Mount  Bracket:    For  installations  in  open  tanks  and  sumps,  use  the  LM50  series  side  mount 

bracket.   

a. For  the  LU77  series,  order  the  LM50‐1001‐1,  which  includes  a  2”  thread  x  1”  thread  reducer 

bushing.   

b. For the LU74 & LU78, Series, order the LM50‐1001 side mount bracket. 

 

LM50‐1001 Shown 

 
 

 

 
 

 