Burkert Type 8619 User Manual

Page 91

Advertising
background image

89

Adjustmentandcommissioning

VOLUME TEACH: Determine the K factor unique to your installation using a teach-in procedure by volume.
Follow the procedure below.

FLOW TEACH: Determine the K factor unique to your installation using a teach-in procedure by flow rate.
Follow the procedure on next page.

Detailed procedure for teach-in by volume

Prepare a tank capable of containing 100 litres, for example;

Choose the volume unit and the flow rate unit in which the teach-in is run:

Mx:Inputs

Calibration

DI1/2: Flow

M0:Inputs

Volume teaching

L

m3

gal
Igal

Volume unit

L/h

Igal/s

Flow unit

...

Running teach-in by volume:

Open the valve to fill the tank.

The multiCELL displays the K factor calculated
by teach-in.

OK

The multiCELL displays the
instantaneous flow rate of the fluid.

OK

When the tank is filled, close the valve.

OK

2.001 l/s

The multiCELL displays the
volume calculated with the
current K factor.

Enter the actual volume of fluid in
the tank.

101.2 l
+099.0 l

Volume teaching

Calibration

DI1:/DI2:Flow

M0:Inputs

Start teaching

Meas. in progr.

Flowed volume

Flow K factor:
K=3,810

Teaching result

Type 8619

english