Quickstart, English – Burkert Type 8175 User Manual

Page 74

Advertising
background image

6

8175

ENGLISH

QUICKSTART

Choose filters 0-2 if no echo filtering
of obstructing obstacles is required
and filters 3-9 if echo filtering is
required.

Typically 331.4 m/s within the air with
a deviation of 0.59m/s/°C.

To determine a new zero point and
sound velocity.

For ex. 4mA -> 100cm
and 20mA -> 250cm

2.2 PROGRAMMING

The electronics within the 8175 ultrasonic level transmitter allows the unit to be configura-
ted as either distance, level or volume depending on the application.

To access the CALIBRATION MENU simutaneously press

ENTER

for 5 seconds.

-

The ‘Enter‘ key can be locked to avoid accidental or unauthorised access - section 3.3.

-

Reference can additionally be made to the menu guide - section 4.2.

2.2.1

Programming - distance

Choose the

desired language

Select the desired

units

Select the desired

filter

Enter the

Sound velocity

Perform a Teach-In

procedure

Enter the current

output range

Configure relays

1 & 2 (If available)

Measurement or Simulation (optional)

See section 4.4.1

See section 4.4.2

See section 4.4.3

See section 4.4.4

See section 4.4.6

See section 4.4.7

See section 4.4.8

See section 2.3

Advertising