CALIBRATION MENU

4.4 CALIBRATION MENU

PRESS

ENTER

SIMULTANEOUSLY FOR 5 SECONDS

The following parameters can be set within this menu:

The following sections explain how to change the parameter values within the calibration
menu above.

0......9

UNIT

FILTER

ECHO

TEACH-IN

RELAY

END

LANGUAGE

GAS COMP

CURRENT

Function

Paragraph

Selection between English, German, French,
Italian or Spanish.

4.4.1

Selection of engineering units for level, distance
or volume.

4.4.2

Damping selection and delay time setting for
signal failure alarm. There are ten different steps
available. (Range 0 to 9).

4.4.3

Gas characteristics (velocity of sound and tem-
perature influence).

4.4.4

Selection of the target level and if there are any
fixed echos to be filtered and eliminated by the
transmitter.

4.4.5

Manual or automatic determination of the speci-
fic application parameters.

4.4.6

Setting of the 4-20mA output signal range.

4.4.7

Parameter definition of relays 1 & 2.

4.4.8

Back to the operation mode; store the new
parameters set.