CTI Products RCD Standard - Remote Comparator Display User Manual

Page 100

Advertising
background image

MCN Remote Comparator Display

Appendix A

CTI Products, Inc.

Changing Status Message Text

68-10856-210

94

Creating 4 sub-categories
Table 10 shows how four sub-categories can be created by reserving the FAIL and
the DISABLE input status signals (binary weight 40 hex and 20 hex) for the
selector. Up to 4 status messages can be defined for each sub-category, with the
VOTE and RECEIVE input status signals selecting between the status messages
in each sub-category.

Input

Value

Field

Sub-

category

Sub-Category

Selector I/O Bits

FAIL DISABLE

Active Status Signals

00

0

0 0

-

01

0

0 0

VOTE

04

0

0 0

RECEIVE

05

0

0 0

RECEIVE + VOTE

10

1

0 1

-

11

1

0 1

VOTE

14

1

0 1

RECEIVE

15

1

0 1

RECEIVE + VOTE

40

2

1 0

-

41

2

1 0

VOTE

44

2

1 0

RECEIVE

45

2

1 0

RECEIVE + VOTE

50

3

1 1

-

51

3

1 1

VOTE

54

3

1 1

RECEIVE

55

3

1 1

RECEIVE + VOTE

Table 10 - 4 Sub-categories / 4 States Each

Note: In Table 10, any bit or input status signal shown as a 1 is an active input
signal and any bit shown as a 0 is an inactive input signal. For the MCN system,
all I/O signals are active low, so any active input status signal is low at the CIB or
IOB I/O connector and any inactive input status signal is high at the CIB or IOB
I/O connector.

Advertising