Input value for comparator i/o systems, Nput, Alue – CTI Products RCD Standard - Remote Comparator Display User Manual

Page 78: Omparator, I/o s, Ystems, Ven in section 9.3

Advertising
background image

MCN Remote Comparator Display

Appendix A

CTI Products, Inc.

Changing Status Message Text

68-10856-210

72

9.4.1 Input Value For Comparator I/O Systems

Each receiver’s status is described by a single byte of status information received
from the Comparator I/O Modules. The status information byte format is defined
in Table 4. Any value not shown in the table results in an ERROR status display
(“Err”). The “x” bits in the table indicate input value bits that can be either a 0 or
a 1, therefore both conditions of this bit must be accounted in separate text
definition lines of the MCNRCD.CFG file.

Bits

76 54 32 10

State

00 00 00 00

IDLE

00 00 0x 01

VOTE

00 00 01 00

RX

0x 01 0x 00

DISABLE

01 00 0x 00

FAIL

00 00 00 10

TX

00 00 0x 11

TX/VOTE

00 00 01 10

TX/RX

0x 01 0x 10

TX/DISABLE

01 00 0x 10

TX/FAIL

Table 4 - Input Value Format

Note: In Table 4, any bit position shown as a 1 is an active input signal and any
bit shown as a 0 is an inactive input signal. For the MCN system, all I/O signals
are active low, so any active input signal is low at the CIB or IOB I/O connector
and any inactive input signal is high at the CIB or IOB I/O connector.

From Table 4 you can see that one condition defines an IDLE state:

1.

00 00 00 00 : IDLE

For this IDLE state, the displayed text defined in MCNRCD.CFG must be a single
space. The color video attribute for this state must be 1F hex and the black and
white video attribute for this state must be 0F hex.

Two conditions define a VOTE state:

1.

00 00 00 01 : VOTE

2.

00 00 01 01 : VOTE + RX

Only one condition defines a RX state:

1.

00 00 01 00 : RX

Advertising