Configuring a System

CTI Products, Inc.

Using MCNCFG

68-10856-210

29

using the Edit HIB Address command. Figure 16 shows the dialog box that
appears.

Figure 16 - HIB Address Entry Dialog Box

To enter a new address for the HIB or PCLTA, do the following:

1.

For the Group number, enter a number between 00 and FE (hex). The

default Group number is 80 (hex).

2.

T

over to the Module number field and enter a number between 0 and

F (hex).

3.

T

over to the <OK> button and press

E

to save the new address.

Every screen file must have the correct HIB or PCLTA address programmed.

All MCN modules in a system must have its own unique address. Each
MCNRCD screen files on a single PC should have the same unit address assigned
to them and all PCs should be assigned to a unique unit address. When assigning
addresses to the modules, you may want to reserve a single MCN Group (or
cluster of Groups if you have more than 16 HIBs and PCLTAs in the system) for
all of the HIBs and PCLTAs. Typically, Group numbers 80 and up are used for
HIBs and PCLTAs.

6.5.5 Adding Channel Titles to the Display Screen

If you display multiple channels on a screen, you will probably want to add
channel titles to help the user identify the receivers. Channel Titles can be 18-
characters long.