MCN Remote Comparator Display

Appendix A

CTI Products, Inc.

Changing Status Message Text

68-10856-210

95

Creating 8 sub-categories
Table 11 shows how eight sub-categories can be created by reserving the FAIL,
DISABLE and RECEIVE input status signals (binary weight 40 hex, 20 hex and
10 hex) for the selector. Two status messages can be defined for each sub-
category, with the VOTE input status signal selecting between the messages.

Input

Value

Field

Sub-

category

Sub-category Selector I/O

Bits

FAIL DISABLE RECEIVE

Active
Status

Signals

00

0

0 0 0

-

01

0

0 0 0

VOTE

04

1

0 0 1

-

05

1

0 0 1

VOTE

10

2

0 1 0

-

11

2

0 1 0

VOTE

14

3

0 1 1

-

15

3

0 1 1

VOTE

40

4

1 0 0

-

41

4

1 0 0

VOTE

44

5

1 0 1

-

45

5

1 0 1

VOTE

50

6

1 1 0

-

51

6

1 1 0

VOTE

54

7

1 1 1

-

55

7

1 1 1

VOTE

Table 11 - 8 Sub-categories / 2 States Each

Note: In Table 11, any bit or input status signal shown as a 1 is an active input
signal and any bit shown as a 0 is an inactive input signal. For the MCN system,
all I/O signals are active low, so any active input status signal is low at the CIB or
IOB I/O connector and any inactive input status signal is high at the CIB or IOB
I/O connector.

Advertising