CTI Products RCD Standard - Remote Comparator Display User Manual

Page 92

Advertising
background image

MCN Remote Comparator Display

Appendix A

CTI Products, Inc.

Changing Status Message Text

68-10856-210

86

; Control Category
[CONTROL]
VOTE=L
DISABLE=L
00 00 1F 0F 0 04 00 0000 00000 0 00 "Idle "
01 01 2F 70 0 04 00 0000 00000 0 00 "On"
02 04 70 70 0 04 00 0000 00000 0 00 "Off"
03 10 E0 70 1 04 00 0000 00000 0 00 "Run"
03 50 E0 70 1 04 00 0000 00000 0 00 "Stop"
04 00 6E 70 1 04 00 0000 00000 0 00 "Err"

<OUTPUT>
378 00 00
378 FE 01
378 FD 02
378 FB 04
378 F7 08
378 EF 10
378 DF 20
378 BF 40
378 7F 80
378 FE 00
378 FD 00
378 FB 00
378 F7 00
378 EF 00
378 DF 00
378 BF 00
378 7F 00

<PORT INIT>

<AUDIO>
N72 P8 N72 P8 N72
N58 P8 N40
N61 P8 N61 P8 N61

Figure 34 - Multiple Category MCNRCD.CFG File

When we create the Group Configuration File for this system, we must change the
category names assigned to the two Input/Output Control Modules. The
Comparator I/O Module’s assigned category name does not need to be changed
since this module will use the category DEFAULT (MCNRCD automatically
assigns the category name DEFAULT to each module when the MCF file is
created). The category names are changed using the Edit Module Config
command in MCNCFG.EXE (see section 6.4.5). Figure 35 shows what the
MODULE CONFIGURATION screen will look like after you change the category
names. A simple module description was also entered for each module. Notice
that the category names are assigned to the specific Module number of the MCN
I/O modules.