MCN Remote Comparator Display

Appendix A

CTI Products, Inc.

Changing Status Message Text

68-10856-210

93

Creating 2 sub-categories
Table 9 shows how two sub-categories can be created by reserving the FAIL input
status signal (binary weight 40 hex) for the selector. Up to 8 status messages can
be defined for each sub-category, with the VOTE, RECEIVE and DISABLE input
status signals selecting between each status message.

Input

Value

Field

Sub-

category

#

Sub-Category

Selector I/O Bit

FAIL

Active Status Signals

00

0

0

-

01

0

0

VOTE

04

0

0

RECEIVE

05

0

0

RECEIVE + VOTE

10

0

0

DISABLE

11

0

0

DISABLE + VOTE

14

0

0

DISABLE + RECEIVE

15

0

0

DISABLE + RECEIVE + VOTE

40

1

1

-

41

1

1

VOTE

44

1

1

RECEIVE

45

1

1

RECEIVE + VOTE

50

1

1

DISABLE

51

1

1

DISABLE + VOTE

54

1

1

DISABLE + RECEIVE

55

1

1

DISABLE + RECEIVE + VOTE

Table 9 - 2 Sub-categories / 8 States Each

Note: In Table 9, any bit or input status signal shown as a 1 is an active input
signal and any bit shown as a 0 is an inactive input signal. For the MCN system,
all I/O signals are active low, so any active input status signal is low at the CIB or
IOB I/O connector and any inactive input status signal is high at the CIB or IOB
I/O connector.