CTI Products RCD Standard - Remote Comparator Display User Manual

Page 94

Advertising
background image

MCN Remote Comparator Display

Appendix A

CTI Products, Inc.

Changing Status Message Text

68-10856-210

88

After the Group Configuration File is created, the Screen Configuration File can
be created. Figure 37 shows the MCNRCD display for the screen configuration
entered.

Figure 37 - Multiple Category Screen File

Using this screen configuration, along with the MCNRCD.CFG file given in
Figure 34, we can now display status messages customized for each MCN I/O
device in our system. Table 7 shows which status text will be displayed by
MCNRCD for each MCN I/O module when the specific input values are received.

Input

Value

Comparator

I/O Module

Input/Output

Control Module 1

Input/Output

Control Module 2

01

Vote

Active

On

04

Rx

Fail

Off

10

Dis

Err

Run

50

Dis

Err

Stop

44

Fail

Access

Err

Table 7 - Multiple Category Text Display

The output controls for each category in Figure 37 are setup to operate as shown
in Table 8.