Data storage method – IAI America IA-T-XD User Manual

Page 17

Advertising
background image

8. Data Storage Method

Since the X-SEL Controller adopts flash memory, there is a storage area by battery backup and a

storage area by flash memory according to the data to be stored.

In addition, even if data is transferred from the PC software or Teaching Pendant, the data is only

to be written in memory as shown in the chart below and the data is erased by power-off or

controller reset.

To ensure data storage, write the data you want to store in flash memory.

8-1.

Factory setting: When system memory backup battery is used

Other parameter No. 20 = 2 (Backup battery installed)

Edit data with PC or

Teaching Pendant

Data maintained during

power-on and erased

by reset

Data maintained even after power-off

Flash writing

Program

parameter

(content 1)

Symbol

Flash

memory

Memory

Transfer

Reset reading

Transfer

Slave card

parameter

(content 2)

Memory

Transfer

Reset reading

Transfer

* Encoder

parameter

Memory

* Encoder

Transfer

Reset reading

Position

coordinate

system data

Battery

backup

memory

Flash

memory

Transfer

Flash writing

Battery

backup

memory

SEL global data

(content 3)

Error list

Transfer

* Encoder parameters are not stored within the controller but in the EEPROM of the actuator’s

encoder itself. They are read into the controller at power-on or software-reset time.

14

Advertising
This manual is related to the following products: