Connection to controller – IAI America IA-T-XD User Manual

Page 7

Advertising
background image

5. Connection to Controller

Teaching Pendant

AC power

Class D grounding

(Protective ground)

Output voltage: 24V DC±10%
Capacity: 20 – 30W

24V DC power
for brake
(Customer supplied)

M cable

Tool, control unit, etc.
(Customer supplied)

Z-axis/R-axis brake release switch

PG cable

U cable
(User wiring cable)

BK power cable

Standard cable length: 5 m

① Connect the actuator, I/O 24V DC power source and system I/O to the controller, in advance.

Connect the cable connector of the Teaching Pendant to the controller’s teaching connector

when the main power supply of the controller is OFF.

② After flipping the MODE switch of the controller to MANU, turn on the power to the controller.

Teaching Pendant

LCD display

It displays the version of the Teaching Pendant and
moves to the Mode Selection screen.

When the MODE switch is flipped to AUTO, the
Teaching Pendant is not connected to the controller
and the screen at the left is displayed. Press the

ESC key to make it a reconnection display.

4