2. when system memory backup battery is not used – IAI America IA-T-XD User Manual

Page 18

Advertising
background image

Since the program, parameter, and symbol are read from flash memory at restart time, the data in

memory becomes the original data before editing unless the data is written in flash memory.

The controller always operates according to the data in memory (within the dotted box) excluding

parameters.

Content 1: Parameters excluding content 2 below and encoder parameters

Content 2: Driver card and IO slot card (power-supply system card) parameters

Content 3: Flags, variables, strings

8-2.

When system memory backup battery is not used

Other parameter No. 20 = 0 (Backup battery not installed)

Edit data with PC or

Teaching Pendant

Data maintained during

power-on and erased by

reset

Data maintained even after

power-off

Program

Parameter

(content 1)

Symbol

Position

Coordinate

system data

Flash writing

Flash

memory

Memory

Transfer

Reset reading

Transfer

Slave card

parameter

(content 2)

Memory

Transfer

Reset reading

Transfer

* Encoder

parameter

* Encoder

Transfer

Memory

Reset reading

SEL global data

(content 3)

Error list

Memory

Transfer

Since the program, parameter, symbol, position, and coordinate system data are read from flash

memory at restart time, the data in memory becomes the original data before editing unless the

data is written in flash memory.

The controller always operates according to the data in memory (within the dotted box) excluding

parameters.

Note: The SEL global data cannot be maintained when the backup battery is not installed.