IAI America IA-T-XD User Manual

Page 50

Advertising
background image

(1) Teaching screen

The teaching screen consists of two screens including 'position No. selection screen' and

'axis-specific data input screen.

On the position No. selection screen, teaching (current-position incorporation/clear) is given to all

axes simultaneously. On the axis-specific data input screen, teaching is given on an axis basis.

Function key descriptions


F1(Disp): It switches the display between the

input data screen and the current
position display.

F2(Scan): It incorporates the current positions

of all axes onto the screen.

F3(Clr):

It clears the all-axis data of the
position No. selected.

F4(JCrd): It changes the coordinate system for

jog operation.



F1(Vel):

It inputs data of velocity, etc., for each
position No.

F2(JVel):

It sets the jog velocity, etc.

F3(MVel): It sets movement velocity in the

continuous movement mode (Cont)
or with the MOVE key.

F4(Arm): It changes the arm system. (Servo

ON status required in advance)

Note: The arm operates.



F1(Crd#): It selects the coordinate system No.
F2(In):

It monitors input ports.

F3(Out):

It monitors output ports.

F4(UsrO): It turns ON/OFF the output ports

(sequential 8 points at the maximum
set to parameters).
(It is required to set the I/O
parameters No. 74 and No. 75.)

Position No. selection screen


F1(Cont): It moves to the continuous movement

mode.

F2(Jump): It sets jump movement.

(Teaching Pendant Application Part
Ver. 1.13 or later)

Enter the position No. with the ten-key numeric pad, and press the return key to move to the

axis-specific data input screen.