Removing user-assigned protocol assignments – Teledyne LeCroy Merlin - Users Manual User Manual

Page 137

Advertising
background image

129

BTTracer Protocol Analyzer User’s Manual

CATC

SW Version 2.0

To open the Decoding Assignments dialog box and reassign a protocol,

Step 1

Select from the menu
View>Decoding assignments

The Decoding Assignments dialog box will open. A status message in

the bottom left corner of the dialog box will indicate who assigned the
protocol.

Step 2

Click on one of the displayed assignments.

If the protocol was assigned by Merlin, the Assign buttons on the right
will be grayed out and unavailable. If you want to change these
assignments, you will have to use the pop-up menus described in the
previous section. If a protocol has been manually assigned by a user, the
Assign buttons will become active and allow you to make a change in
assignment.

Step 3

If possible, click the appropriate Assign button.

Removing User-Assigned Protocol Assignments

As you practice assigning and reassigning protocols, you will find that one
of the more useful commands is "Remove All User Assignments." This
command allows you to undo all of your assignments.

To remove some or all user-assigned protocol assignments,

Step 1

Double-click any Protocol Message header to open view
L2CAP messages.

Step 2

Locate a message with a field marked "A."

Step 3

Left-click on the "A" field to open the Assignment menu.

Step 4

Select "Remove All User assignments" or "Remove this
assignment."

Advertising