Merlin Protocol Analyzer User’s Manual

CATC

SW Version 2.0

Drive strength for all outputs is about 30mA high (@2V) and 60 mA low
(@0.5V). Inputs can handle 0 to 5.5V. Inputs above 2V are detected as logic
high; inputs below 0.8V are detected as logic low.

The Breakout Board connects via a cable to the Data In/Out connector
located on the rear of the analyzer unit. Each signaling pin is isolated by a
100

Ω series resistor and a buffer inside the Analyzer unit.

Data In/Out Connector (on cable)

Pin-Outs for the Data In/Out Connector

The following table lists the pin-out and signal descriptions for the Data
In/Out
connector on a cable that connects to the Breakout board.

Data In/Out Connector – Pin-Out

Pin

Signal Name

Signal Description

1

RSV

Reserved

2

GND

Ground

3

GP OUT

General Purpose Output

4

TRG IN 1

Trigger In 1

5

GND

Ground

6

DATA 6

Data 6

7

DATA 4

Data 4

8

DATA 3

Data 3

9

DATA 1

Data 1

10

GND

Ground

11

RSV

Reserved

12

RSV

Reserved

13

+5V

+5 Volts, 250 mA DC Source

14

RSV

Reserved

15

GND

Ground

16

TRG OUT

Trigger Out

17

TRG IN 0

Trigger In 0

18

DATA 7

Data 7

19

DATA 5

Data 5

20

GND

Ground

21

DATA 2

Data 2

22

DATA 0

Data 0