Series 146 – Watlow Series 146 Retrofit User Manual

Page 100

Advertising
background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-3629-2S00

24 VAC

T t/c

-328 to 662°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5MY -328 0622 A

2, 6, 8

146E-3629-2S00

24 VAC

T t/c

-200 to 350°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5NY -200 0350 A

2, 6, 8

146E-3629-3000

24 VAC

T t/c

-328 to 662°F

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6MU -328 0622 A

6, 8

146E-3629-3000

24 VAC

T t/c

-200 to 350°C

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6NW -200 0350 A

6, 8

146E-3629-3N00

24 VAC

T t/c

-328 to 662°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5MU -328 0622 A

2, 6, 8

146E-3629-3N00

24 VAC

T t/c

-200 to 350°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5NW -200 0350 A

2, 6, 8

146E-3629-3P00

24 VAC

T t/c

-328 to 662°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5MU -328 0622 A

2, 6, 8

146E-3629-3P00

24 VAC

T t/c

-200 to 350°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5NW -200 0350 A

2, 6, 8

146E-3629-3S00

24 VAC

T t/c

-328 to 662°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5MU -328 0622 A

2, 6, 8

146E-3629-3S00

24 VAC

T t/c

-200 to 350°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5NW -200 0350 A

2, 6, 8

146E-3629-4000

24 VAC

T t/c

-328 to 662°F

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6MZ -328 0622 A

6, 8

146E-3629-4000

24 VAC

T t/c

-200 to 350°C

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6NY -200 0350 A

6, 8

146E-3629-4N00

24 VAC

T t/c

-328 to 662°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5MZ -328 0622 A

2, 6, 8

146E-3629-4N00

24 VAC

T t/c

-200 to 350°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5NY -200 0350 A

2, 6, 8

146E-3629-4P00

24 VAC

T t/c

-328 to 662°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5MZ -328 0622 A

2, 6, 8

146E-3629-4P00

24 VAC

T t/c

-200 to 350°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5NY -200 0350 A

2, 6, 8

146E-3629-4S00

24 VAC

T t/c

-328 to 662°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5MZ -328 0622 A

2, 6, 8

146E-3629-4S00

24 VAC

T t/c

-200 to 350°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5NY -200 0350 A

2, 6, 8

146E-3632-1000

25 VAC

T t/c

-103°F

High Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6MU -103 AAAA A

6, 8

146E-3632-1000

26 VAC

T t/c

-75°C

High Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6NU -075 AAAA A

6, 8

146E-3632-2000

27 VAC

T t/c

-103°F

Low Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6MY -103 AAAA A

6, 8

146E-3632-2000

28 VAC

T t/c

-75°C

Low Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6NY -075 AAAA A

6, 8

146E-3632-3000

29 VAC

T t/c

-103°F

High Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6MW -103 AAAA A

6, 8

146E-3632-3000

30 VAC

T t/c

-75°C

High Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6NW -075 AAAA A

6, 8

146E-3632-4000

31 VAC

T t/c

-103°F

Low Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6MZ -103 AAAA A

6, 8

146E-3632-4000

32 VAC

T t/c

-75°C

Low Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6NZ -075 AAAA A

6, 8

146E-3633-1000

33 VAC

J t/c

650°F

High Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6HU 0650 AAAA A

6, 8

146E-3633-1000

34 VAC

J t/c

343°C

High Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6JU 0343 AAAA A

6, 8

146E-3633-2000

35 VAC

J t/c

650°F

Low Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6HY 0650 AAAA A

6, 8

146E-3633-2000

36 VAC

J t/c

343°C

Low Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6JY 0343 AAAA A

6, 8

146E-3633-3000

37 VAC

J t/c

650°F

High Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6HW 0650 AAAA A

6, 8

146E-3633-3000

38 VAC

J t/c

343°C

High Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6JW 0343 AAAA A

6, 8

146E-3633-4000

39 VAC

J t/c

650°F

Low Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6HZ 0650 AAAA A

6, 8

146E-3633-4000

40 VAC

J t/c

343°C

Low Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6JZ 0343 AAAA A

6, 8

146E-3634-1000

41 VAC

K t/c

280°F

High Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6KU 0280 AAAA A

6, 8

146E-3634-1000

42 VAC

K t/c

138°C

High Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6LU 0138 AAAA A

6, 8

146E-3634-2000

43 VAC

K t/c

280°F

Low Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6KY 0280 AAAA A

6, 8

146E-3634-2000

44 VAC

K t/c

138°C

Low Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6LY 0138 AAAA A

6, 8

146E-3634-3000

45 VAC

K t/c

280°F

High Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6KW 0280 AAAA A

6, 8

146E-3634-3000

46 VAC

K t/c

138°C

High Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6LW 0138 AAAA A

6, 8

146E-3634-4000

47 VAC

K t/c

280°F

Low Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6KZ 0280 AAAA A

6, 8

Watlow Controls

3/30/2005

Page 95

Advertising