Series 146 – Watlow Series 146 Retrofit User Manual

Page 34

Advertising
background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146D-3K4F-3100

24 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6KW 0032 0150 A

6

146D-3K4F-3200

24 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5KW 0032 0150 A

2, 6

146D-3K4F-4100

24 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6KZ 0032 0150 A

6

146D-3K4F-4200

24 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G6KZ 0032 0150 A

6

146D-3K5C-1100

24 VAC

K t/c

-17 to 315°C

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6LU -017 0315 A

6

146D-3K5C-1200

24 VAC

K t/c

-17 to 315°C

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5LU -017 0315 A

2, 6

146D-3K5C-2100

24 VAC

K t/c

-17 to 315°C

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6LY -017 0315 A

6

146D-3K5C-2200

24 VAC

K t/c

-17 to 315°C

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5LY -017 0315 A

2, 6

146D-3K5C-3100

24 VAC

K t/c

-17 to 315°C

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6LW -017 0315 A

6

146D-3K5C-3200

24 VAC

K t/c

-17 to 315°C

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5LW -017 0315 A

2, 6

146D-3K5C-4100

24 VAC

K t/c

-17 to 315°C

Low Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6LZ -017 0315 A

6

146D-3K5C-4200

24 VAC

K t/c

-17 to 315°C

Low Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5LZ -017 0315 A

2, 6

146D-3K5D-1100

24 VAC

K t/c

0 to 600°F

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6KU 0000 0600 A

6, 8

146D-3K5D-1100

24 VAC

K t/c

-17 to 315°C

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6LU -017 0315 A

6, 8

146D-3K5D-1200

24 VAC

K t/c

0 to 600°F

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5KU 0000 0600 A

2, 6, 8

146D-3K5D-1200

24 VAC

K t/c

-17 to 315°C

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5LU -017 0315 A

2, 6, 8

146D-3K5D-2100

24 VAC

K t/c

0 to 600°F

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6KY 0000 0600 A

6, 8

146D-3K5D-2100

24 VAC

K t/c

-17 to 315°C

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6LY -017 0315 A

6, 8

146D-3K5D-2200

24 VAC

K t/c

0 to 600°F

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5KY 0000 0600 A

2, 6, 8

146D-3K5D-2200

24 VAC

K t/c

-17 to 315°C

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5LY -017 0315 A

2, 6, 8

146D-3K5D-3100

24 VAC

K t/c

0 to 600°F

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6KW 0000 0600 A

6, 8

146D-3K5D-3100

24 VAC

K t/c

-17 to 315°C

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6LW -017 0315 A

6, 8

146D-3K5D-3200

24 VAC

K t/c

0 to 600°F

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5KW 0000 0600 A

2, 6, 8

146D-3K5D-3200

24 VAC

K t/c

-17 to 315°C

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5LW -017 0315 A

2, 6, 8

146D-3K5D-4100

24 VAC

K t/c

0 to 600°F

Low Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6KZ 0000 0600 A

6, 8

146D-3K5D-4100

24 VAC

K t/c

-17 to 315°C

Low Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6LZ -017 0315 A

6, 8

146D-3K5D-4200

24 VAC

K t/c

0 to 600°F

Low Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5KZ 0000 0600 A

2, 6, 8

146D-3K5D-4200

24 VAC

K t/c

-17 to 315°C

Low Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5LZ -017 0315 A

2, 6, 8

146D-3K5F-1100

24 VAC

K t/c

0 to 600°F

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6KU 0000 0600 A

6

146D-3K5F-1200

24 VAC

K t/c

0 to 600°F

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5KU 0000 0600 A

2, 6

146D-3K5F-2100

24 VAC

K t/c

0 to 600°F

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6KY 0000 0600 A

6

146D-3K5F-2200

24 VAC

K t/c

0 to 600°F

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5KY 0000 0600 A

2, 6

146D-3K5F-3100

24 VAC

K t/c

0 to 600°F

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6KW 0000 0600 A

6

146D-3K5F-3200

24 VAC

K t/c

0 to 600°F

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5KW 0000 0600 A

2, 6

146D-3K5F-4100

24 VAC

K t/c

0 to 600°F

Low Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6KZ 0000 0600 A

6

146D-3K5F-4200

24 VAC

K t/c

0 to 600°F

Low Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5KZ 0000 0600 A

2, 6

146D-3P1C-1100

24 VAC

100 ohm DIN

-73 to 600°C

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6RU -073 0600 A

6

146D-3P1C-1200

24 VAC

100 ohm DIN

-73 to 600°C

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5RU -073 0600 A

2, 6

146D-3P1C-2100

24 VAC

100 ohm DIN

-73 to 600°C

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6RY -073 0600 A

6

146D-3P1C-2200

24 VAC

100 ohm DIN

-73 to 600°C

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5RY -073 0600 A

2, 6

146D-3P1C-3100

24 VAC

100 ohm DIN

-73 to 600°C

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6RW -073 0600 A

6

Watlow Controls

3/30/2005

Page 29