Series 146 – Watlow Series 146 Retrofit User Manual

Page 98

Advertising
background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-3626-4P00

24 VAC

K t/c

60 to 300°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5KZ 0060 0300 A

2, 6, 8

146E-3626-4P00

24 VAC

K t/c

16 to 149°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5LY 0016 0149 A

2, 6, 8

146E-3626-4S00

24 VAC

K t/c

60 to 300°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5KZ 0060 0300 A

2, 6, 8

146E-3626-4S00

24 VAC

K t/c

16 to 149°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5LY 0016 0149 A

2, 6, 8

146E-3627-1000

24 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6KU 0032 0150 A

6, 8

146E-3627-1000

24 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6LU 0000 0066 A

6, 8

146E-3627-1N00

24 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5KU 0032 0150 A

2, 6, 8

146E-3627-1N00

24 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5LU 0000 0066 A

2, 6, 8

146E-3627-1P00

24 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5KU 0032 0150 A

2, 6, 8

146E-3627-1P00

24 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5LU 0000 0066 A

2, 6, 8

146E-3627-1S00

24 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5KU 0032 0150 A

2, 6, 8

146E-3627-1S00

24 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5LU 0000 0066 A

2, 6, 8

146E-3627-2000

24 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6KY 0032 0150 A

6, 8

146E-3627-2000

24 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6LY 0000 0066 A

6, 8

146E-3627-2N00

24 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5KY 0032 0150 A

2, 6, 8

146E-3627-2N00

24 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5LY 0000 0066 A

2, 6, 8

146E-3627-2P00

24 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5KY 0032 0150 A

2, 6, 8

146E-3627-2P00

24 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5LY 0000 0066 A

2, 6, 8

146E-3627-2S00

24 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5KY 0032 0150 A

2, 6, 8

146E-3627-2S00

24 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5LY 0000 0066 A

2, 6, 8

146E-3627-3000

24 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6KW 0032 0150 A

6, 8

146E-3627-3000

24 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6LW 0000 0066 A

6, 8

146E-3627-3N00

24 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5KW 0032 0150 A

2, 6, 8

146E-3627-3N00

24 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5LW 0000 0066 A

2, 6, 8

146E-3627-3P00

24 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5KW 0032 0150 A

2, 6, 8

146E-3627-3P00

24 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5LW 0000 0066 A

2, 6, 8

146E-3627-3S00

24 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5KW 0032 0150 A

2, 6, 8

146E-3627-3S00

24 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5LW 0000 0066 A

2, 6, 8

146E-3627-4000

24 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6KZ 0032 0150 A

6, 8

146E-3627-4000

24 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6LY 0000 0066 A

6, 8

146E-3627-4N00

24 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5KZ 0032 0150 A

2, 6, 8

146E-3627-4N00

24 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5LY 0000 0066 A

2, 6, 8

146E-3627-4P00

24 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5KZ 0032 0150 A

2, 6, 8

146E-3627-4P00

24 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5LY 0000 0066 A

2, 6, 8

146E-3627-4S00

24 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5KZ 0032 0150 A

2, 6, 8

146E-3627-4S00

24 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5LY 0000 0066 A

2, 6, 8

146E-3628-1000

24 VAC

K t/c

0 to 600°F

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6KU 0000 0600 A

6, 8

146E-3628-1000

24 VAC

K t/c

-17 to 315°C

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6LU -017 0315 A

6, 8

146E-3628-1N00

24 VAC

K t/c

0 to 600°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5KU 0000 0600 A

2, 6, 8

146E-3628-1N00

24 VAC

K t/c

-17 to 315°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5LU -017 0315 A

2, 6, 8

146E-3628-1P00

24 VAC

K t/c

0 to 600°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5KU 0000 0600 A

2, 6, 8

Watlow Controls

3/30/2005

Page 93

Advertising