Series 146 – Watlow Series 146 Retrofit User Manual

Page 102

Advertising
background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-3J1C-1100

24 VAC

J t/c

0 to 315°C

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6JU 0000 0315 A

3, 6

146E-3J1C-1200

24 VAC

J t/c

0 to 315°C

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5JU 0000 0315 A

2, 3, 6

146E-3J1C-2100

24 VAC

J t/c

0 to 315°C

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6JY 0000 0315 A

3, 6

146E-3J1C-2200

24 VAC

J t/c

0 to 315°C

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5JY 0000 0315 A

2, 3, 6

146E-3J1C-3100

24 VAC

J t/c

0 to 315°C

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6JW 0000 0315 A

3, 6

146E-3J1C-3200

24 VAC

J t/c

0 to 315°C

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5JW 0000 0315 A

2, 3, 6

146E-3J1C-4100

24 VAC

J t/c

0 to 315°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6JZ 0000 0315 A

3, 6

146E-3J1C-4200

24 VAC

J t/c

0 to 315°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5JZ 0000 0315 A

2, 3, 6

146E-3J1D-1100

24 VAC

J t/c

32 to 600°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6HU 0032 0600 A

3, 6, 8

146E-3J1D-1100

24 VAC

J t/c

0 to 315°C

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6JU 0000 0315 A

3, 6, 8

146E-3J1D-1200

24 VAC

J t/c

32 to 600°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5HU 0032 0600 A

2, 3, 6, 8

146E-3J1D-1200

24 VAC

J t/c

0 to 315°C

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5JU 0000 0315 A

2, 3, 6, 8

146E-3J1D-2100

24 VAC

J t/c

32 to 600°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6HY 0032 0600 A

3, 6, 8

146E-3J1D-2100

24 VAC

J t/c

0 to 315°C

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6JY 0000 0315 A

3, 6, 8

146E-3J1D-2200

24 VAC

J t/c

32 to 600°F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5HY 0032 0600 A

2, 3, 6, 8

146E-3J1D-2200

24 VAC

J t/c

0 to 315°C

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5JY 0000 0315 A

2, 3, 6, 8

146E-3J1D-3100

24 VAC

J t/c

32 to 600°F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6HW 0032 0600 A

3, 6, 8

146E-3J1D-3100

24 VAC

J t/c

0 to 315°C

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6JW 0000 0315 A

3, 6, 8

146E-3J1D-3200

24 VAC

J t/c

32 to 600°F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5HW 0032 0600 A

2, 3, 6, 8

146E-3J1D-3200

24 VAC

J t/c

0 to 315°C

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5JW 0000 0315 A

2, 3, 6, 8

146E-3J1D-4100

24 VAC

J t/c

32 to 600°F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6HZ 0032 0600 A

3, 6, 8

146E-3J1D-4100

24 VAC

J t/c

0 to 315°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6JZ 0000 0315 A

3, 6, 8

146E-3J1D-4200

24 VAC

J t/c

32 to 600°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5HZ 0032 0600 A

2, 3, 6, 8

146E-3J1D-4200

24 VAC

J t/c

0 to 315°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5JZ 0000 0315 A

2, 3, 6, 8

146E-3J1F-1100

24 VAC

J t/c

32 to 600°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6HU 0032 0600 A

3, 6

146E-3J1F-1200

24 VAC

J t/c

32 to 600°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5HU 0032 0600 A

2, 3, 6

146E-3J1F-2100

24 VAC

J t/c

32 to 600°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6HY 0032 0600 A

3, 6

146E-3J1F-2200

24 VAC

J t/c

32 to 600°F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5HY 0032 0600 A

2, 3, 6

146E-3J1F-3100

24 VAC

J t/c

32 to 600°F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6HW 0032 0600 A

3, 6

146E-3J1F-3200

24 VAC

J t/c

32 to 600°F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5HW 0032 0600 A

2, 3, 6

146E-3J1F-4100

24 VAC

J t/c

32 to 600°F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6HZ 0032 0600 A

3, 6

146E-3J1F-4200

24 VAC

J t/c

32 to 600°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5HZ 0032 0600 A

2, 3, 6

146E-3J2C-1100

24 VAC

J t/c

0 to 750°C

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6JU 0000 0750 A

3, 6

146E-3J2C-1200

24 VAC

J t/c

0 to 750°C

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5JU 0000 0750 A

2, 3, 6

146E-3J2C-2100

24 VAC

J t/c

0 to 750°C

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6JY 0000 0750 A

3, 6

146E-3J2C-2200

24 VAC

J t/c

0 to 750°C

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5JY 0000 0750 A

2, 3, 6

146E-3J2C-3100

24 VAC

J t/c

0 to 750°C

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6JW 0000 0750 A

3, 6

146E-3J2C-3200

24 VAC

J t/c

0 to 750°C

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5JW 0000 0750 A

2, 3, 6

146E-3J2C-4100

24 VAC

J t/c

0 to 750°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6JZ 0000 0750 A

3, 6

146E-3J2C-4200

24 VAC

J t/c

0 to 750°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5JZ 0000 0750 A

2, 3, 6

146E-3J2D-1100

24 VAC

J t/c

32 to 1382°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6HU 0032 1382 A

3, 6, 8

Watlow Controls

3/30/2005

Page 97

Advertising