Series 146 – Watlow Series 146 Retrofit User Manual

Page 94

Advertising
background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-3618-4000

24 VAC

J t/c

0 to 200°F

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6HZ 0000 0200 A

6, 8

146E-3618-4000

24 VAC

J t/c

-17 to 93°C

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6JZ -017 0093 A

6, 8

146E-3618-4N00

24 VAC

J t/c

0 to 200°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HZ 0000 0200 A

2, 6, 8

146E-3618-4N00

24 VAC

J t/c

-17 to 93°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JZ -017 0093 A

2, 6, 8

146E-3618-4P00

24 VAC

J t/c

0 to 200°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HZ 0000 0200 A

2, 6, 8

146E-3618-4P00

24 VAC

J t/c

-17 to 93°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JZ -017 0093 A

2, 6, 8

146E-3618-4S00

24 VAC

J t/c

0 to 200°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HZ 0000 0200 A

2, 6, 8

146E-3618-4S00

24 VAC

J t/c

-17 to 93°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JZ -017 0093 A

2, 6, 8

146E-3619-1000

24 VAC

E t/c

32 to 1470°F

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6SU 0032 1470 A

6, 8

146E-3619-1000

24 VAC

E t/c

0 to 799°C

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6TU 0000 0799 A

6, 8

146E-3619-1N00

24 VAC

E t/c

32 to 1470°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5SU 0032 1470 A

2, 6, 8

146E-3619-1N00

24 VAC

E t/c

0 to 799°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5TU 0000 0799 A

2, 6, 8

146E-3619-1P00

24 VAC

E t/c

32 to 1470°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5SU 0032 1470 A

2, 6, 8

146E-3619-1P00

24 VAC

E t/c

0 to 799°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5TU 0000 0799 A

2, 6, 8

146E-3619-1S00

24 VAC

E t/c

32 to 1470°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5SU 0032 1470 A

2, 6, 8

146E-3619-1S00

24 VAC

E t/c

0 to 799°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5TU 0000 0799 A

2, 6, 8

146E-3619-2000

24 VAC

E t/c

32 to 1470°F

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6SY 0032 1470 A

6, 8

146E-3619-2000

24 VAC

E t/c

0 to 799°C

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6TY 0000 0799 A

6, 8

146E-3619-2N00

24 VAC

E t/c

32 to 1470°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5SY 0032 1470 A

2, 6, 8

146E-3619-2N00

24 VAC

E t/c

0 to 799°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5TY 0000 0799 A

2, 6, 8

146E-3619-2P00

24 VAC

E t/c

32 to 1470°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5SY 0032 1470 A

2, 6, 8

146E-3619-2P00

24 VAC

E t/c

0 to 799°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5TY 0000 0799 A

2, 6, 8

146E-3619-2S00

24 VAC

E t/c

32 to 1470°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5SY 0032 1470 A

2, 6, 8

146E-3619-2S00

24 VAC

E t/c

0 to 799°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5TY 0000 0799 A

2, 6, 8

146E-3619-3000

24 VAC

E t/c

32 to 1470°F

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6SW 0032 1470 A

6, 8

146E-3619-3000

24 VAC

E t/c

0 to 799°C

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6TW 0000 0799 A

6, 8

146E-3619-3N00

24 VAC

E t/c

32 to 1470°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5SW 0032 1470 A

2, 6, 8

146E-3619-3N00

24 VAC

E t/c

0 to 799°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5TW 0000 0799 A

2, 6, 8

146E-3619-3P00

24 VAC

E t/c

32 to 1470°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5SW 0032 1470 A

2, 6, 8

146E-3619-3P00

24 VAC

E t/c

0 to 799°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5TW 0000 0799 A

2, 6, 8

146E-3619-3S00

24 VAC

E t/c

32 to 1470°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5SW 0032 1470 A

2, 6, 8

146E-3619-3S00

24 VAC

E t/c

0 to 799°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5TW 0000 0799 A

2, 6, 8

146E-3619-4000

24 VAC

E t/c

32 to 1470°F

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6SZ 0032 1470 A

6, 8

146E-3619-4000

24 VAC

E t/c

0 to 799°C

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6TZ 0000 0799 A

6, 8

146E-3619-4N00

24 VAC

E t/c

32 to 1470°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5SZ 0032 1470 A

2, 6, 8

146E-3619-4N00

24 VAC

E t/c

0 to 799°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5TZ 0000 0799 A

2, 6, 8

146E-3619-4P00

24 VAC

E t/c

32 to 1470°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5SZ 0032 1470 A

2, 6, 8

146E-3619-4P00

24 VAC

E t/c

0 to 799°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5TZ 0000 0799 A

2, 6, 8

146E-3619-4S00

24 VAC

E t/c

32 to 1470°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5SZ 0032 1470 A

2, 6, 8

146E-3619-4S00

24 VAC

E t/c

0 to 799°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5TZ 0000 0799 A

2, 6, 8

146E-3620-1000

24 VAC

J t/c

300 to 800°F

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6HU 0300 0800 A

6, 8

Watlow Controls

3/30/2005

Page 89