Series 146 – Watlow Series 146 Retrofit User Manual

Page 101

Advertising
background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-3634-4000

48 VAC

K t/c

138°C

Low Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6LZ 0138 AAAA A

6, 8

146E-3637-1000

49 VAC

K t/c

450°F

High Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6KU 0450 AAAA A

6, 8

146E-3637-1000

50 VAC

K t/c

232°C

High Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6LU 0232 AAAA A

6, 8

146E-3637-2000

51 VAC

K t/c

450°F

Low Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6KY 0450 AAAA A

6, 8

146E-3637-2000

52 VAC

K t/c

232°C

Low Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6LY 0232 AAAA A

6, 8

146E-3637-3000

53 VAC

K t/c

450°F

High Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6KW 0450 AAAA A

6, 8

146E-3637-3000

54 VAC

K t/c

232°C

High Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6LW 0232 AAAA A

6, 8

146E-3637-4000

55 VAC

K t/c

450°F

Low Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6KZ 0450 AAAA A

6, 8

146E-3637-4000

56 VAC

K t/c

232°C

Low Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6LZ 0232 AAAA A

6, 8

146E-3E1C-1100

24 VAC

E t/c

0 to 799°C

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6TU 0000 0799 A

3, 6

146E-3E1C-1200

24 VAC

E t/c

0 to 799°C

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5TU 0000 0799 A

2, 3, 6

146E-3E1C-2100

24 VAC

E t/c

0 to 799°C

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6TY 0000 0799 A

3, 6

146E-3E1C-2200

24 VAC

E t/c

0 to 799°C

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5TY 0000 0799 A

2, 3, 6

146E-3E1C-3100

24 VAC

E t/c

0 to 799°C

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6TW 0000 0799 A

3, 6

146E-3E1C-3200

24 VAC

E t/c

0 to 799°C

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5TW 0000 0799 A

2, 3, 6

146E-3E1C-4100

24 VAC

E t/c

0 to 799°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6TZ 0000 0799 A

3, 6

146E-3E1C-4200

24 VAC

E t/c

0 to 799°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5TZ 0000 0799 A

2, 3, 6

146E-3E1D-1100

24 VAC

E t/c

32 to 1470°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6SU 0032 1470 A

3, 6, 8

146E-3E1D-1100

24 VAC

E t/c

0 to 799°C

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6TU 0000 0799 A

3, 6, 8

146E-3E1D-1200

24 VAC

E t/c

32 to 1470°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5SU 0032 1470 A

2, 3, 6, 8

146E-3E1D-1200

24 VAC

E t/c

0 to 799°C

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5TU 0000 0799 A

2, 3, 6, 8

146E-3E1D-2100

24 VAC

E t/c

32 to 1470°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6SY 0032 1470 A

3, 6, 8

146E-3E1D-2100

24 VAC

E t/c

0 to 799°C

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6TY 0000 0799 A

3, 6, 8

146E-3E1D-2200

24 VAC

E t/c

32 to 1470°F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5SY 0032 1470 A

2, 3, 6, 8

146E-3E1D-2200

24 VAC

E t/c

0 to 799°C

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5TY 0000 0799 A

2, 3, 6, 8

146E-3E1D-3100

24 VAC

E t/c

32 to 1470°F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6SW 0032 1470 A

3, 6, 8

146E-3E1D-3100

24 VAC

E t/c

0 to 799°C

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6TW 0000 0799 A

3, 6, 8

146E-3E1D-3200

24 VAC

E t/c

32 to 1470°F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5SW 0032 1470 A

2, 3, 6, 8

146E-3E1D-3200

24 VAC

E t/c

0 to 799°C

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5TW 0000 0799 A

2, 3, 6, 8

146E-3E1D-4100

24 VAC

E t/c

32 to 1470°F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6SZ 0032 1470 A

3, 6, 8

146E-3E1D-4100

24 VAC

E t/c

0 to 799°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6TZ 0000 0799 A

3, 6, 8

146E-3E1D-4200

24 VAC

E t/c

32 to 1470°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5SZ 0032 1470 A

2, 3, 6, 8

146E-3E1D-4200

24 VAC

E t/c

0 to 799°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5TZ 0000 0799 A

2, 3, 6, 8

146E-3E1F-1100

24 VAC

E t/c

32 to 1470°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6SU 0032 1470 A

3, 6

146E-3E1F-1200

24 VAC

E t/c

32 to 1470°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5SU 0032 1470 A

2, 3, 6

146E-3E1F-2100

24 VAC

E t/c

32 to 1470°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6SY 0032 1470 A

3, 6

146E-3E1F-2200

24 VAC

E t/c

32 to 1470°F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5SY 0032 1470 A

2, 3, 6

146E-3E1F-3100

24 VAC

E t/c

32 to 1470°F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6SW 0032 1470 A

3, 6

146E-3E1F-3200

24 VAC

E t/c

32 to 1470°F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5SW 0032 1470 A

2, 3, 6

146E-3E1F-4100

24 VAC

E t/c

32 to 1470°F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6SZ 0032 1470 A

3, 6

146E-3E1F-4200

24 VAC

E t/c

32 to 1470°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5SZ 0032 1470 A

2, 3, 6

Watlow Controls

3/30/2005

Page 96

Advertising