Series 146 – Watlow Series 146 Retrofit User Manual

Page 68

Advertising
background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-2611-3S00

230 VAC

K t/c

32 to 1112°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KW 0032 1112 A

2, 6, 8

146E-2611-3S00

230 VAC

K t/c

0 to 600°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LW 0000 0600 A

2, 6, 8

146E-2611-4000

230 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6KZ 0032 1112 A

6, 8

146E-2611-4000

230 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6LZ 0000 0600 A

6, 8

146E-2611-4N00

230 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KZ 0032 1112 A

2, 6, 8

146E-2611-4N00

230 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LZ 0000 0600 A

2, 6, 8

146E-2611-4P00

230 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KZ 0032 1112 A

2, 6, 8

146E-2611-4P00

230 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LZ 0000 0600 A

2, 6, 8

146E-2611-4S00

230 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KZ 0032 1112 A

2, 6, 8

146E-2611-4S00

230 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LZ 0000 0600 A

2, 6, 8

146E-2615-1000

230 VAC

J t/c

315°C

High Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF E6HU 0315 AAAA A

6, 8

146E-2615-1000

230 VAC

J t/c

600°F

High Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF E6HU 0600 AAAA A

6, 8

146E-2615-2000

230 VAC

J t/c

600°F

Low Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF E6HY 0600 AAAA A

6, 8

146E-2615-2000

230 VAC

J t/c

315°C

Low Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF E6HY0315 AAAA A

6, 8

146E-2615-3000

230 VAC

J t/c

315°C

High Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF E6HUW0315 AAAA A

6, 8

146E-2615-3000

230 VAC

J t/c

600°F

High Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF E6HW 0600 AAAA A

6, 8

146E-2615-4000

230 VAC

J t/c

600°F

Low Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF E6HZ 0600 AAAA A

6, 8

146E-2615-4000

230 VAC

J t/c

315°C

Low Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF E6HZ0315 AAAA A

6, 8

146E-2618-1000

230 VAC

J t/c

0 to 200°F

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6HU 0000 0200 A

6, 8

146E-2618-1000

230 VAC

J t/c

-17 to 93°C

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6JU -017 0093 A

6, 8

146E-2618-1N00

230 VAC

J t/c

0 to 200°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5HU 0000 0200 A

2, 6, 8

146E-2618-1N00

230 VAC

J t/c

-17 to 93°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5JU -017 0093 A

2, 6, 8

146E-2618-1P00

230 VAC

J t/c

0 to 200°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5HU 0000 0200 A

2, 6, 8

146E-2618-1P00

230 VAC

J t/c

-17 to 93°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5JU -017 0093 A

2, 6, 8

146E-2618-1S00

230 VAC

J t/c

0 to 200°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5HU 0000 0200 A

2, 6, 8

146E-2618-1S00

230 VAC

J t/c

-17 to 93°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5JU -017 0093 A

2, 6, 8

146E-2618-2000

230 VAC

J t/c

0 to 200°F

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6HY 0000 0200 A

6, 8

146E-2618-2000

230 VAC

J t/c

-17 to 93°C

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6JY -017 0093 A

6, 8

146E-2618-2N00

230 VAC

J t/c

0 to 200°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5HY 0000 0200 A

2, 6, 8

146E-2618-2N00

230 VAC

J t/c

-17 to 93°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5JY -017 0093 A

2, 6, 8

146E-2618-2P00

230 VAC

J t/c

0 to 200°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5HY 0000 0200 A

2, 6, 8

146E-2618-2P00

230 VAC

J t/c

-17 to 93°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5JY -017 0093 A

2, 6, 8

146E-2618-2S00

230 VAC

J t/c

0 to 200°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5HY 0000 0200 A

2, 6, 8

146E-2618-2S00

230 VAC

J t/c

-17 to 93°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5JY -017 0093 A

2, 6, 8

146E-2618-3000

230 VAC

J t/c

0 to 200°F

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6HW 0000 0200 A

6, 8

146E-2618-3000

230 VAC

J t/c

-17 to 93°C

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6JW -017 0093 A

6, 8

146E-2618-3N00

230 VAC

J t/c

0 to 200°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5HW 0000 0200 A

2, 6, 8

146E-2618-3N00

230 VAC

J t/c

-17 to 93°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5JW -017 0093 A

2, 6, 8

146E-2618-3P00

230 VAC

J t/c

0 to 200°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5HW 0000 0200 A

2, 6, 8

146E-2618-3P00

230 VAC

J t/c

-17 to 93°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5JW -017 0093 A

2, 6, 8

146E-2618-3S00

230 VAC

J t/c

0 to 200°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5HW 0000 0200 A

2, 6, 8

Watlow Controls

3/30/2005

Page 63

Advertising