Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-3625-3N00

24 VAC

J t/c

121 to 221°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JW 0121 0221 A

2, 6, 8

146E-3625-3P00

24 VAC

J t/c

250 to 430°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HW 0250 0430 A

2, 6, 8

146E-3625-3P00

24 VAC

J t/c

121 to 221°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JW 0121 0221 A

2, 6, 8

146E-3625-3S00

24 VAC

J t/c

250 to 430°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HW 0250 0430 A

2, 6, 8

146E-3625-3S00

24 VAC

J t/c

121 to 221°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JW 0121 0221 A

2, 6, 8

146E-3625-4000

24 VAC

J t/c

250 to 430°F

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6HZ 0250 0430 A

6, 8

146E-3625-4000

24 VAC

J t/c

121 to 221°C

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6JY 0121 0221 A

6, 8

146E-3625-4N00

24 VAC

J t/c

250 to 430°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HZ 0250 0430 A

2, 6, 8

146E-3625-4N00

24 VAC

J t/c

121 to 221°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JY 0121 0221 A

2, 6, 8

146E-3625-4P00

24 VAC

J t/c

250 to 430°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HZ 0250 0430 A

2, 6, 8

146E-3625-4P00

24 VAC

J t/c

121 to 221°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JY 0121 0221 A

2, 6, 8

146E-3625-4S00

24 VAC

J t/c

250 to 430°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HZ 0250 0430 A

2, 6, 8

146E-3625-4S00

24 VAC

J t/c

121 to 221°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JY 0121 0221 A

2, 6, 8

146E-3626-1000

24 VAC

K t/c

60 to 300°F

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6KU 0060 0300 A

6, 8

146E-3626-1000

24 VAC

K t/c

16 to 149°C

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6LU 0016 0149 A

6, 8

146E-3626-1N00

24 VAC

K t/c

60 to 300°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5KU 0060 0300 A

2, 6, 8

146E-3626-1N00

24 VAC

K t/c

16 to 149°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5LU 0016 0149 A

2, 6, 8

146E-3626-1P00

24 VAC

K t/c

60 to 300°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5KU 0060 0300 A

2, 6, 8

146E-3626-1P00

24 VAC

K t/c

16 to 149°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5LU 0016 0149 A

2, 6, 8

146E-3626-1S00

24 VAC

K t/c

60 to 300°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5KU 0060 0300 A

2, 6, 8

146E-3626-1S00

24 VAC

K t/c

16 to 149°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5LU 0016 0149 A

2, 6, 8

146E-3626-2000

24 VAC

K t/c

60 to 300°F

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6KY 0060 0300 A

6, 8

146E-3626-2000

24 VAC

K t/c

16 to 149°C

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6LY 0016 0149 A

6, 8

146E-3626-2N00

24 VAC

K t/c

60 to 300°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5KY 0060 0300 A

2, 6, 8

146E-3626-2N00

24 VAC

K t/c

16 to 149°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5LY 0016 0149 A

2, 6, 8

146E-3626-2P00

24 VAC

K t/c

60 to 300°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5KY 0060 0300 A

2, 6, 8

146E-3626-2P00

24 VAC

K t/c

16 to 149°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5LY 0016 0149 A

2, 6, 8

146E-3626-2S00

24 VAC

K t/c

60 to 300°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5KY 0060 0300 A

2, 6, 8

146E-3626-2S00

24 VAC

K t/c

16 to 149°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5LY 0016 0149 A

2, 6, 8

146E-3626-3000

24 VAC

K t/c

60 to 300°F

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6KW 0060 0300 A

6, 8

146E-3626-3000

24 VAC

K t/c

16 to 149°C

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6LW 0016 0149 A

6, 8

146E-3626-3N00

24 VAC

K t/c

60 to 300°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5KW 0060 0300 A

2, 6, 8

146E-3626-3N00

24 VAC

K t/c

16 to 149°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5LW 0016 0149 A

2, 6, 8

146E-3626-3P00

24 VAC

K t/c

60 to 300°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5KW 0060 0300 A

2, 6, 8

146E-3626-3P00

24 VAC

K t/c

16 to 149°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5LW 0016 0149 A

2, 6, 8

146E-3626-3S00

24 VAC

K t/c

60 to 300°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5KW 0060 0300 A

2, 6, 8

146E-3626-3S00

24 VAC

K t/c

16 to 149°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5LW 0016 0149 A

2, 6, 8

146E-3626-4000

24 VAC

K t/c

60 to 300°F

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6KZ 0060 0300 A

6, 8

146E-3626-4000

24 VAC

K t/c

16 to 149°C

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6LY 0016 0149 A

6, 8

146E-3626-4N00

24 VAC

K t/c

60 to 300°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5KZ 0060 0300 A

2, 6, 8

146E-3626-4N00

24 VAC

K t/c

16 to 149°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5LY 0016 0149 A

2, 6, 8