Series 146 – Watlow Series 146 Retrofit User Manual

Page 93

Advertising
background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-3611-3S00

24 VAC

K t/c

0 to 600°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5LW 0000 0600 A

2, 6, 8

146E-3611-4000

24 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6KZ 0032 1112 A

6, 8

146E-3611-4000

24 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6LZ 0000 0600 A

6, 8

146E-3611-4N00

24 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5KZ 0032 1112 A

2, 6, 8

146E-3611-4N00

24 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5LZ 0000 0600 A

2, 6, 8

146E-3611-4P00

24 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5KZ 0032 1112 A

2, 6, 8

146E-3611-4P00

24 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5LZ 0000 0600 A

2, 6, 8

146E-3611-4S00

24 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5KZ 0032 1112 A

2, 6, 8

146E-3611-4S00

24 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5LZ 0000 0600 A

2, 6, 8

146E-3615-1000

24 VAC

J t/c

315°C

High Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6HU 0315 AAAA A

6, 8

146E-3615-1000

24 VAC

J t/c

600°F

High Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6HU 0600 AAAA A

6, 8

146E-3615-2000

24 VAC

J t/c

315°C

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LF G6HY 0315 AAAA A

6, 8

146E-3615-2000

24 VAC

J t/c

600°F

Low Limit

Manual Reset

8A Relay

Fixed

DIN Rail

LF G6HY 0600 AAAA A

6, 8

146E-3615-3000

24 VAC

J t/c

315°C

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LF G6HW 0315 AAAA A

6, 8

146E-3615-3000

24 VAC

J t/c

600°F

High Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6HW 0600 AAAA A

6, 8

146E-3615-4000

24 VAC

J t/c

315°C

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LF G6HZ 0315 AAAA A

6, 8

146E-3615-4000

24 VAC

J t/c

600°F

Low Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6HZ 0600 AAAA A

6, 8

146E-3618-1000

24 VAC

J t/c

0 to 200°F

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6HU 0000 0200 A

6, 8

146E-3618-1000

24 VAC

J t/c

-17 to 93°C

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6JU -017 0093 A

6, 8

146E-3618-1N00

24 VAC

J t/c

0 to 200°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HU 0000 0200 A

2, 6, 8

146E-3618-1N00

24 VAC

J t/c

-17 to 93°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JU -017 0093 A

2, 6, 8

146E-3618-1P00

24 VAC

J t/c

0 to 200°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HU 0000 0200 A

2, 6, 8

146E-3618-1P00

24 VAC

J t/c

-17 to 93°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JU -017 0093 A

2, 6, 8

146E-3618-1S00

24 VAC

J t/c

0 to 200°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HU 0000 0200 A

2, 6, 8

146E-3618-1S00

24 VAC

J t/c

-17 to 93°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JU -017 0093 A

2, 6, 8

146E-3618-2000

24 VAC

J t/c

0 to 200°F

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6HY 0000 0200 A

6, 8

146E-3618-2000

24 VAC

J t/c

-17 to 93°C

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6JY -017 0093 A

6, 8

146E-3618-2N00

24 VAC

J t/c

0 to 200°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HY 0000 0200 A

2, 6, 8

146E-3618-2N00

24 VAC

J t/c

-17 to 93°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JY -017 0093 A

2, 6, 8

146E-3618-2P00

24 VAC

J t/c

0 to 200°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HY 0000 0200 A

2, 6, 8

146E-3618-2P00

24 VAC

J t/c

-17 to 93°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JY -017 0093 A

2, 6, 8

146E-3618-2S00

24 VAC

J t/c

0 to 200°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HY 0000 0200 A

2, 6, 8

146E-3618-2S00

24 VAC

J t/c

-17 to 93°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JY -017 0093 A

2, 6, 8

146E-3618-3000

24 VAC

J t/c

0 to 200°F

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6HW 0000 0200 A

6, 8

146E-3618-3000

24 VAC

J t/c

-17 to 93°C

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6JW -017 0093 A

6, 8

146E-3618-3N00

24 VAC

J t/c

0 to 200°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HW 0000 0200 A

2, 6, 8

146E-3618-3N00

24 VAC

J t/c

-17 to 93°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JW -017 0093 A

2, 6, 8

146E-3618-3P00

24 VAC

J t/c

0 to 200°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HW 0000 0200 A

2, 6, 8

146E-3618-3P00

24 VAC

J t/c

-17 to 93°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JW -017 0093 A

2, 6, 8

146E-3618-3S00

24 VAC

J t/c

0 to 200°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HW 0000 0200 A

2, 6, 8

146E-3618-3S00

24 VAC

J t/c

-17 to 93°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JW -017 0093 A

2, 6, 8

Watlow Controls

3/30/2005

Page 88

Advertising