Series 146 – Watlow Series 146 Retrofit User Manual

Page 7

Advertising
background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146D-1J1D-1100

120 VAC

J t/c

0 to 315°C

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV C6JU 0000 0315 A

6, 8

146D-1J1D-1200

120 VAC

J t/c

32 to 600°F

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV C5HU 0032 0600 A

2, 6, 8

146D-1J1D-1200

120 VAC

J t/c

0 to 315°C

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV C5JU 0000 0315 A

2, 6, 8

146D-1J1D-2100

120 VAC

J t/c

32 to 600°F

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV C6HY 0032 0600 A

6, 8

146D-1J1D-2100

120 VAC

J t/c

0 to 315°C

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV C6JY 0000 0315 A

6, 8

146D-1J1D-2200

120 VAC

J t/c

32 to 600°F

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV C5HY 0032 0600 A

2, 6, 8

146D-1J1D-2200

120 VAC

J t/c

0 to 315°C

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV C5JY 0000 0315 A

2, 6, 8

146D-1J1D-3100

120 VAC

J t/c

32 to 600°F

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV C6HW 0032 0600 A

6, 8

146D-1J1D-3100

120 VAC

J t/c

0 to 315°C

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV C6JW 0000 0315 A

6, 8

146D-1J1D-3200

120 VAC

J t/c

32 to 600°F

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV C5HW 0032 0600 A

2, 6, 8

146D-1J1D-3200

120 VAC

J t/c

0 to 315°C

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV C5JW 0000 0315 A

2, 6, 8

146D-1J1D-4100

120 VAC

J t/c

32 to 600°F

Low Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV C6HZ 0032 0600 A

6, 8

146D-1J1D-4100

120 VAC

J t/c

0 to 315°C

Low Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV C6JZ 0000 0315 A

6, 8

146D-1J1D-4200

120 VAC

J t/c

32 to 600°F

Low Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV C5HZ 0032 0600 A

2, 6, 8

146D-1J1D-4200

120 VAC

J t/c

0 to 315°C

Low Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV C5JZ 0000 0315 A

2, 6, 8

146D-1J1F-1100

120 VAC

J t/c

32 to 600°F

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV C6HU 0032 0600 A

6

146D-1J1F-1200

120 VAC

J t/c

32 to 600°F

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV C5HU 0032 0600 A

2, 6

146D-1J1F-2100

120 VAC

J t/c

32 to 600°F

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV C6HY 0032 0600 A

6

146D-1J1F-2200

120 VAC

J t/c

32 to 600°F

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV C5HY 0032 0600 A

2, 6

146D-1J1F-3100

120 VAC

J t/c

32 to 600°F

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV C6HW 0032 0600 A

6

146D-1J1F-3200

120 VAC

J t/c

32 to 600°F

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV C5HW 0032 0600 A

2, 6

146D-1J1F-4100

120 VAC

J t/c

32 to 600°F

Low Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV C6HZ 0032 0600 A

6

146D-1J1F-4200

120 VAC

J t/c

32 to 600°F

Low Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV C5HZ 0032 0600 A

2, 6

146D-1J2C-1100

120 VAC

J t/c

0 to 750°C

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV C6JU 0000 0750 A

6

146D-1J2C-1200

120 VAC

J t/c

0 to 750°C

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV C5JU 0000 0750 A

2, 6

146D-1J2C-2100

120 VAC

J t/c

0 to 750°C

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV C6JY 0000 0750 A

6

146D-1J2C-2200

120 VAC

J t/c

0 to 750°C

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV C5JY 0000 0750 A

2, 6

146D-1J2C-3100

120 VAC

J t/c

0 to 750°C

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV C6JW 0000 0750 A

6

146D-1J2C-3200

120 VAC

J t/c

0 to 750°C

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV C5JW 0000 0750 A

2, 6

146D-1J2C-4100

120 VAC

J t/c

0 to 750°C

Low Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV C6JZ 0000 0750 A

6

146D-1J2C-4200

120 VAC

J t/c

0 to 750°C

Low Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV C5JZ 0000 0750 A

2, 6

146D-1J2D-1100

120 VAC

J t/c

32 to 1382°F

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV C6HU 0032 1382 A

6, 8

146D-1J2D-1100

120 VAC

J t/c

0 to 750°C

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV C6JU 0000 0750 A

6, 8

146D-1J2D-1200

120 VAC

J t/c

32 to 1382°F

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV C5HU 0032 1382 A

2, 6, 8

146D-1J2D-1200

120 VAC

J t/c

0 to 750°C

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV C5JU 0000 0750 A

2, 6, 8

146D-1J2D-2100

120 VAC

J t/c

32 to 1382°F

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV C6HY 0032 1382 A

6, 8

146D-1J2D-2100

120 VAC

J t/c

0 to 750°C

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV C6JY 0000 0750 A

6, 8

146D-1J2D-2200

120 VAC

J t/c

32 to 1382°F

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV C5HY 0032 1382 A

2, 6, 8

146D-1J2D-2200

120 VAC

J t/c

0 to 750°C

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV C5JY 0000 0750 A

2, 6, 8

146D-1J2D-3100

120 VAC

J t/c

32 to 1382°F

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV C6HW 0032 1382 A

6, 8

146D-1J2D-3100

120 VAC

J t/c

0 to 750°C

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV C6JW 0000 0750 A

6, 8

Watlow Controls

3/30/2005

Page 2

Advertising