Series 146 – Watlow Series 146 Retrofit User Manual

Page 58

Advertising
background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-1K3D-4100

120 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6KZ 0032 1112 A

3, 6, 8

146E-1K3D-4100

120 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6LZ 0000 0600 A

3, 6, 8

146E-1K3D-4200

120 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5KZ0032 1112 A

2, 3, 6, 8

146E-1K3D-4200

120 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5LZ 0000 0600 A

2, 3, 6, 8

146E-1K3F-1100

120 VAC

K t/c

32 to 1112°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6KU 0032 1112 A

3, 6

146E-1K3F-1200

120 VAC

K t/c

32 to 1112°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5KU 0032 1112 A

2, 3, 6

146E-1K3F-2100

120 VAC

K t/c

32 to 1112°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6KY0032 1112 A

3, 6

146E-1K3F-2200

120 VAC

K t/c

32 to 1112°F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5KY 0032 1112 A

2, 3, 6

146E-1K3F-3100

120 VAC

K t/c

32 to 1112°F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6KW 0032 1112 A

3, 6

146E-1K3F-3200

120 VAC

K t/c

32 to 1112°F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5KW 0032 1112 A

2, 3, 6

146E-1K3F-4100

120 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6KZ 0032 1112 A

3, 6

146E-1K3F-4200

120 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5KZ0032 1112 A

2, 3, 6

146E-1K4C-1100

120 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6LU 0000 0066 A

3, 6

146E-1K4C-1200

120 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5LU 0000 0066 A

2, 3, 6

146E-1K4C-2100

120 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6LY 0000 0066 A

3, 6

146E-1K4C-2200

120 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5LY 0000 0066 A

2, 3, 6

146E-1K4C-3100

120 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6LW 0000 0066 A

3, 6

146E-1K4C-3200

120 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5LW 0000 0066 A

2, 3, 6

146E-1K4C-4100

120 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6LZ 0000 0066 A

3, 6

146E-1K4C-4200

120 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5LZ 0000 0066 A

2, 3, 6

146E-1K4D-1100

120 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6KU 0032 0150 A

3, 6, 8

146E-1K4D-1100

120 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6LU 0000 0066 A

3, 6, 8

146E-1K4D-1200

120 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5KU 0032 0150 A

2, 3, 6, 8

146E-1K4D-1200

120 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5LU 0000 0066 A

2, 3, 6, 8

146E-1K4D-2100

120 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6KY 0032 0150 A

3, 6, 8

146E-1K4D-2100

120 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6LY 0000 0066 A

3, 6, 8

146E-1K4D-2200

120 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5KY 0032 0150 A

2, 3, 6, 8

146E-1K4D-2200

120 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5LY 0000 0066 A

2, 3, 6, 8

146E-1K4D-3100

120 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6KW 0032 0150 A

3, 6, 8

146E-1K4D-3100

120 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6LW 0000 0066 A

3, 6, 8

146E-1K4D-3200

120 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5KW 0032 0150 A

2, 3, 6, 8

146E-1K4D-3200

120 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5LW 0000 0066 A

2, 3, 6, 8

146E-1K4D-4100

120 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6KZ 0032 0150 A

3, 6, 8

146E-1K4D-4100

120 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6LZ 0000 0066 A

3, 6, 8

146E-1K4D-4200

120 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5KZ 0032 0150 A

2, 3, 6, 8

146E-1K4D-4200

120 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5LZ 0000 0066 A

2, 3, 6, 8

146E-1K4F-1100

120 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6KU 0032 0150 A

3, 6

146E-1K4F-1200

120 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5KU 0032 0150 A

2, 3, 6

146E-1K4F-2100

120 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6KY 0032 0150 A

3, 6

146E-1K4F-2200

120 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5KY 0032 0150 A

2, 3, 6

146E-1K4F-3100

120 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6KW 0032 0150 A

3, 6

Watlow Controls

3/30/2005

Page 53