Series 146 – Watlow Series 146 Retrofit User Manual

Page 111

Advertising
background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-3T1D-3100

24 VAC

T t/c

-200 to 350°C

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6NW -200 0350 A

3, 6, 8

146E-3T1D-3200

24 VAC

T t/c

-328 to 662°F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5MW -328 0662 A

2, 3, 6, 8

146E-3T1D-3200

24 VAC

T t/c

-200 to 350°C

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5NW -200 0350 A

2, 3, 6, 8

146E-3T1D-4100

24 VAC

T t/c

-328 to 662°F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6MZ -328 0662 A

3, 6, 8

146E-3T1D-4100

24 VAC

T t/c

-200 to 350°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6NZ -200 0350 A

3, 6, 8

146E-3T1D-4200

24 VAC

T t/c

-328 to 662°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5MZ -328 0662 A

2, 3, 6, 8

146E-3T1D-4200

24 VAC

T t/c

-200 to 350°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5NZ -200 0350 A

2, 3, 6, 8

146E-3T1F-1100

24 VAC

T t/c

-328 to 662°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6MU -328 0662 A

3, 6

146E-3T1F-1200

24 VAC

T t/c

-328 to 662°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5MU -328 0662 A

2, 3, 6

146E-3T1F-2100

24 VAC

T t/c

-328 to 662°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6MY -328 0662 A

3, 6

146E-3T1F-2200

24 VAC

T t/c

-328 to 662°F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5MY -328 0662 A

2, 3, 6

146E-3T1F-3100

24 VAC

T t/c

-328 to 662°F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6MW -328 0662 A

3, 6

146E-3T1F-3200

24 VAC

T t/c

-328 to 662°F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5MW -328 0662 A

2, 3, 6

146E-3T1F-4100

24 VAC

T t/c

-328 to 662°F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6MZ -328 0662 A

3, 6

146E-3T1F-4200

24 VAC

T t/c

-328 to 662°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5MZ -328 0662 A

2, 3, 6

Note 1: Retrofit controller requires a substitution of a 100 Ohm DIN RTD sensor.

Note 2: Mounting and dimensions of retrofit controller are different. Verify that sufficient panel space and depth is available.

Note 3: Retrofit controller outputs are different. Add external interposing mechanical or solid state relay if applicable.

Note 4: Retrofit controller has a programmable, not fixed set point. Lock set point using controller's lockout parameter.

Note 5: For DIN rail mounting or sub-panel mounting, purchase DIN rail adapter p/n 0822-0586-P001 for 1/32 DIN or p/n 0822-0586-P002 for 1/16 DIN.

Note 6: Add a quencharc suppressor, Watlow p/n 0804-0147-0000, for inductive loads.

Note 7: Retrofit does not have equivalent action (as example, no manual reset)

Note 8: Retrofit controller does not have dual dial scale.

Note 9: Hardware lockout is not available on retrofit.

Note 10: Retrofit controller does not have user selectable line voltage.

Note 11: Retrofit does not support remote set point or retransmit. If wires are on these pins, select a different retrofit.

Note 12: Retrofit controller does not have user selectable control action.

Note 13: Solid state sensor required for humidity. See http://www.vaisala.com

Note 14: Retrofit controller does not have user selectable control mode.

Note 15: Use auxiliay event board A007-1732-F4B8

Note 16: Retrofit communications are different, consult specifications.

Note 17: Verify retrofit input range matches application.

Watlow Controls

3/30/2005

Page 106