Series 146 – Watlow Series 146 Retrofit User Manual

Page 45

Advertising
background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-1619-4S00

120 VAC

E t/c

0 to 799°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV C5TZ 0000 0799 A

2, 6, 8

146E-1620-1000

120 VAC

J t/c

300 to 800°F

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV C6HU 0300 0800 A

6, 8

146E-1620-1000

120 VAC

J t/c

149 to 427°C

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV C6JU 0149 0427 A

6, 8

146E-1620-1N00

120 VAC

J t/c

300 to 800°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5HU 0300 0800 A

2, 6, 8

146E-1620-1N00

120 VAC

J t/c

149 to 427°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5JU 0149 0427 A

2, 6, 8

146E-1620-1P00

120 VAC

J t/c

300 to 800°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5HU 0300 0800 A

2, 6, 8

146E-1620-1P00

120 VAC

J t/c

149 to 427°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5JU 0149 0427 A

2, 6, 8

146E-1620-1S00

120 VAC

J t/c

300 to 800°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5HU 0300 0800 A

2, 6, 8

146E-1620-1S00

120 VAC

J t/c

149 to 427°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5JU 0149 0427 A

2, 6, 8

146E-1620-2000

120 VAC

J t/c

300 to 800°F

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV C6HY 0300 0800 A

6, 8

146E-1620-2000

120 VAC

J t/c

149 to 427°C

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV C6JY 0149 0427 A

6, 8

146E-1620-2N00

120 VAC

J t/c

300 to 800°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5HY 0300 0800 A

2, 6, 8

146E-1620-2N00

120 VAC

J t/c

149 to 427°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5JY 0149 0427 A

2, 6, 8

146E-1620-2P00

120 VAC

J t/c

300 to 800°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5HY 0300 0800 A

2, 6, 8

146E-1620-2P00

120 VAC

J t/c

149 to 427°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5JY 0149 0427 A

2, 6, 8

146E-1620-2S00

120 VAC

J t/c

300 to 800°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5HY 0300 0800 A

2, 6, 8

146E-1620-2S00

120 VAC

J t/c

149 to 427°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5JY 0149 0427 A

2, 6, 8

146E-1620-3000

120 VAC

J t/c

300 to 800°F

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV C6HW 0300 0800 A

6, 8

146E-1620-3000

120 VAC

J t/c

149 to 427°C

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV C6JW 0149 0427 A

6, 8

146E-1620-3N00

120 VAC

J t/c

300 to 800°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV C5HW 0300 0800 A

2, 6, 8

146E-1620-3N00

120 VAC

J t/c

149 to 427°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV C5JW 0149 0427 A

2, 6, 8

146E-1620-3P00

120 VAC

J t/c

300 to 800°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV C5HW 0300 0800 A

2, 6, 8

146E-1620-3P00

120 VAC

J t/c

149 to 427°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV C5JW 0149 0427 A

2, 6, 8

146E-1620-3S00

120 VAC

J t/c

300 to 800°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV C5HW 0300 0800 A

2, 6, 8

146E-1620-3S00

120 VAC

J t/c

149 to 427°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV C5JW 0149 0427 A

2, 6, 8

146E-1620-4000

120 VAC

J t/c

300 to 800°F

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV C6HZ 0300 0800 A

6, 8

146E-1620-4000

120 VAC

J t/c

149 to 427°C

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV C6JZ 0149 0427 A

6, 8

146E-1620-4N00

120 VAC

J t/c

300 to 800°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV C5HZ 0300 0800 A

2, 6, 8

146E-1620-4N00

120 VAC

J t/c

149 to 427°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV C5JZ 0149 0427 A

2, 6, 8

146E-1620-4P00

120 VAC

J t/c

300 to 800°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV C5HZ 0300 0800 A

2, 6, 8

146E-1620-4P00

120 VAC

J t/c

149 to 427°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV C5JZ 0149 0427 A

2, 6, 8

146E-1620-4S00

120 VAC

J t/c

300 to 800°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV C5HZ 0300 0800 A

2, 6, 8

146E-1620-4S00

120 VAC

J t/c

149 to 427°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV C5JZ 0149 0427 A

2, 6, 8

146E-1623-1000

120 VAC

J t/c

110 to 130°F

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV C6HU 0110 0130 A

6, 8

146E-1623-1000

120 VAC

J t/c

43 to 54°C

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV C6JU 0043 0054 A

6, 8

146E-1623-1N00

120 VAC

J t/c

110 to 130°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5HU 0110 0130 A

2, 6, 8

146E-1623-1N00

120 VAC

J t/c

43 to 54°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5JU 0043 0054 A

2, 6, 8

146E-1623-1P00

120 VAC

J t/c

110 to 130°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5HU 0110 0130 A

2, 6, 8

146E-1623-1P00

120 VAC

J t/c

43 to 54°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5JU 0043 0054 A

2, 6, 8

146E-1623-1S00

120 VAC

J t/c

110 to 130°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5HU 0110 0130 A

2, 6, 8

146E-1623-1S00

120 VAC

J t/c

43 to 54°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV C5JU 0043 0054 A

2, 6, 8

Watlow Controls

3/30/2005

Page 40

Advertising