Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-1P1C-4100

120 VAC

100 ohm DIN

-73 to 600°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6RZ -073 0600 A

3, 6

146E-1P1C-4200

120 VAC

100 ohm DIN

-73 to 600°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5RZ -073 0600 A

2, 3, 6

146E-1P1D-1100

120 VAC

100 ohm DIN

-73 to 600°C

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6RU -073 0600 A

3, 6, 8

146E-1P1D-1100

120 VAC

100 ohm DIN

-100 to 1112 °F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6PU -100 1112 A

3, 6, 8

146E-1P1D-1200

120 VAC

100 ohm DIN

-73 to 600°C

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5RU -073 0600 A

2, 3, 6, 8

146E-1P1D-1200

120 VAC

100 ohm DIN

-100 to 1112 °F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5PU -100 1112 A

2, 3, 6, 8

146E-1P1D-2100

120 VAC

100 ohm DIN

-73 to 600°C

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6RY -073 0600 A

3, 6, 8

146E-1P1D-2100

120 VAC

100 ohm DIN

-100 to 1112 °F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6PY -100 1112 A

3, 6, 8

146E-1P1D-2200

120 VAC

100 ohm DIN

-73 to 600°C

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5RY -073 0600 A

2, 3, 6, 8

146E-1P1D-2200

120 VAC

100 ohm DIN

-100 to 1112 °F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5PY -100 1112 A

2, 3, 6, 8

146E-1P1D-3100

120 VAC

100 ohm DIN

-73 to 600°C

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6RW -073 0600 A

3, 6, 8

146E-1P1D-3100

120 VAC

100 ohm DIN

-100 to 1112 °F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6PW -100 1112 A

3, 6, 8

146E-1P1D-3200

120 VAC

100 ohm DIN

-73 to 600°C

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5RW -073 0600 A

2, 3, 6, 8

146E-1P1D-3200

120 VAC

100 ohm DIN

-100 to 1112 °F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5PW -100 1112 A

2, 3, 6, 8

146E-1P1D-4100

120 VAC

100 ohm DIN

-73 to 600°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6RZ -073 0600 A

3, 6, 8

146E-1P1D-4100

120 VAC

100 ohm DIN

-100 to 1112 °F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6PZ -100 1112 A

3, 6, 8

146E-1P1D-4200

120 VAC

100 ohm DIN

-73 to 600°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5RZ -073 0600 A

2, 3, 6, 8

146E-1P1D-4200

120 VAC

100 ohm DIN

-100 to 1112 °F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5PZ -100 1112 A

2, 3, 6, 8

146E-1P1F-1100

120 VAC

100 ohm DIN

-100 to 1112 °F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6PU -100 1112 A

3, 6

146E-1P1F-1200

120 VAC

100 ohm DIN

-100 to 1112 °F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5PU -100 1112 A

2, 3, 6

146E-1P1F-2100

120 VAC

100 ohm DIN

-100 to 1112 °F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6PY -100 1112 A

3, 6

146E-1P1F-2200

120 VAC

100 ohm DIN

-100 to 1112 °F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5PY -100 1112 A

2, 3, 6

146E-1P1F-3100

120 VAC

100 ohm DIN

-100 to 1112 °F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6PW -100 1112 A

3, 6

146E-1P1F-3200

120 VAC

100 ohm DIN

-100 to 1112 °F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5PW -100 1112 A

2, 3, 6

146E-1P1F-4100

120 VAC

100 ohm DIN

-100 to 1112 °F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6PZ -100 1112 A

3, 6

146E-1P1F-4200

120 VAC

100 ohm DIN

-100 to 1112 °F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5PZ -100 1112 A

2, 3, 6

146E-1T1C-1100

120 VAC

T t/c

-200 to 350°C

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6NU -200 0350 A

3, 6

146E-1T1C-1200

120 VAC

T t/c

-200 to 350°C

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5NU -200 0350 A

2, 3, 6

146E-1T1C-2100

120 VAC

T t/c

-200 to 350°C

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6NY -200 0350 A

3, 6

146E-1T1C-2200

120 VAC

T t/c

-200 to 350°C

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5NY -200 0350 A

2, 3, 6

146E-1T1C-3100

120 VAC

T t/c

-200 to 350°C

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6NW -200 0350 A

3, 6

146E-1T1C-3200

120 VAC

T t/c

-200 to 350°C

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5NW -200 0350 A

2, 3, 6

146E-1T1C-4100

120 VAC

T t/c

-200 to 350°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6NZ -200 0350 A

3, 6

146E-1T1C-4200

120 VAC

T t/c

-200 to 350°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5NZ -200 0350 A

2, 3, 6

146E-1T1D-1100

120 VAC

T t/c

-328 to 662°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6MU -328 0662 A

3, 6, 8

146E-1T1D-1100

120 VAC

T t/c

-200 to 350°C

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6NU -200 0350 A

3, 6, 8

146E-1T1D-1200

120 VAC

T t/c

-328 to 662°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5MU -328 0662 A

2, 3, 6, 8

146E-1T1D-1200

120 VAC

T t/c

-200 to 350°C

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5NU -200 0350 A

2, 3, 6, 8

146E-1T1D-2100

120 VAC

T t/c

-328 to 662°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6MY -328 0662 A

3, 6, 8

146E-1T1D-2100

120 VAC

T t/c

-200 to 350°C

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6NY -200 0350 A

3, 6, 8

146E-1T1D-2200

120 VAC

T t/c

-328 to 662°F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5MY -328 0662 A