Series 146 – Watlow Series 146 Retrofit User Manual

Page 73

Advertising
background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-2626-4N00

230 VAC

K t/c

16 to 149°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LZ 0016 0149 A

2, 6, 8

146E-2626-4P00

230 VAC

K t/c

60 to 300°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KZ 0060 0300 A

2, 6, 8

146E-2626-4P00

230 VAC

K t/c

16 to 149°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LZ 0016 0149 A

2, 6, 8

146E-2626-4S00

230 VAC

K t/c

60 to 300°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KZ 0060 0300 A

2, 6, 8

146E-2626-4S00

230 VAC

K t/c

16 to 149°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LZ 0016 0149 A

2, 6, 8

146E-2627-1000

230 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6KU 0032 0150 A

6, 8

146E-2627-1000

230 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6LU 0000 0066 A

6, 8

146E-2627-1N00

230 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5KU 0032 0150 A

2, 6, 8

146E-2627-1N00

230 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5LU 0000 0066 A

2, 6, 8

146E-2627-1P00

230 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5KU 0032 0150 A

2, 6, 8

146E-2627-1P00

230 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5LU 0000 0066 A

2, 6, 8

146E-2627-1S00

230 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5KU 0032 0150 A

2, 6, 8

146E-2627-1S00

230 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5LU 0000 0066 A

2, 6, 8

146E-2627-2000

230 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6KY 0032 0150 A

6, 8

146E-2627-2000

230 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6LY 0000 0066 A

6, 8

146E-2627-2N00

230 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5KY 0032 0150 A

2, 6, 8

146E-2627-2N00

230 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5LY 0000 0066 A

2, 6, 8

146E-2627-2P00

230 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5KY 0032 0150 A

2, 6, 8

146E-2627-2P00

230 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5LY 0000 0066 A

2, 6, 8

146E-2627-2S00

230 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5KY 0032 0150 A

2, 6, 8

146E-2627-2S00

230 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5LY 0000 0066 A

2, 6, 8

146E-2627-3000

230 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6KW 0032 0150 A

6, 8

146E-2627-3000

230 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6LW 0000 0066 A

6, 8

146E-2627-3N00

230 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KW 0032 0150 A

2, 6, 8

146E-2627-3N00

230 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LW 0000 0066 A

2, 6, 8

146E-2627-3P00

230 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KW 0032 0150 A

2, 6, 8

146E-2627-3P00

230 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LW 0000 0066 A

2, 6, 8

146E-2627-3S00

230 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KW 0032 0150 A

2, 6, 8

146E-2627-3S00

230 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LW 0000 0066 A

2, 6, 8

146E-2627-4000

230 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6KZ 0032 0150 A

6, 8

146E-2627-4000

230 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6LZ 0000 0066 A

6, 8

146E-2627-4N00

230 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KZ 0032 0150 A

2, 6, 8

146E-2627-4N00

230 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LZ 0000 0066 A

2, 6, 8

146E-2627-4P00

230 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KZ 0032 0150 A

2, 6, 8

146E-2627-4P00

230 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LZ 0000 0066 A

2, 6, 8

146E-2627-4S00

230 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KZ 0032 0150 A

2, 6, 8

146E-2627-4S00

230 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LZ 0000 0066 A

2, 6, 8

146E-2628-1000

230 VAC

K t/c

0 to 600°F

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6KU 0000 0600 A

6, 8

146E-2628-1000

230 VAC

K t/c

-17 to 315°C

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6LU -017 0315 A

6, 8

146E-2628-1N00

230 VAC

K t/c

0 to 600°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5KU 0000 0600 A

2, 6, 8

146E-2628-1N00

230 VAC

K t/c

-17 to 315°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5LU -017 0315 A

2, 6, 8

Watlow Controls

3/30/2005

Page 68

Advertising