Series 146 – Watlow Series 146 Retrofit User Manual

Page 96

Advertising
background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-3623-2N00

24 VAC

J t/c

110 to 130°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HY 0110 0130 A

2, 6, 8

146E-3623-2N00

24 VAC

J t/c

43 to 54°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JY 0043 0054 A

2, 6, 8

146E-3623-2P00

24 VAC

J t/c

110 to 130°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HY 0110 0130 A

2, 6, 8

146E-3623-2P00

24 VAC

J t/c

43 to 54°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JY 0043 0054 A

2, 6, 8

146E-3623-2S00

24 VAC

J t/c

110 to 130°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HY 0110 0130 A

2, 6, 8

146E-3623-2S00

24 VAC

J t/c

43 to 54°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JY 0043 0054 A

2, 6, 8

146E-3623-3000

24 VAC

J t/c

110 to 130°F

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6HW 0110 0130 A

6, 8

146E-3623-3000

24 VAC

J t/c

43 to 54°C

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6JW 0043 0054 A

6, 8

146E-3623-3N00

24 VAC

J t/c

110 to 130°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HW 0110 0130 A

2, 6, 8

146E-3623-3N00

24 VAC

J t/c

43 to 54°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JW 0043 0054 A

2, 6, 8

146E-3623-3P00

24 VAC

J t/c

110 to 130°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HW 0110 0130 A

2, 6, 8

146E-3623-3P00

24 VAC

J t/c

43 to 54°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JW 0043 0054 A

2, 6, 8

146E-3623-3S00

24 VAC

J t/c

110 to 130°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HW 0110 0130 A

2, 6, 8

146E-3623-3S00

24 VAC

J t/c

43 to 54°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JW 0043 0054 A

2, 6, 8

146E-3623-4000

24 VAC

J t/c

110 to 130°F

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6HZ 0110 0130 A

6, 8

146E-3623-4000

24 VAC

J t/c

43 to 54°C

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6JZ 0043 0054 A

6, 8

146E-3623-4N00

24 VAC

J t/c

110 to 130°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HZ 0110 0130 A

2, 6, 8

146E-3623-4N00

24 VAC

J t/c

43 to 54°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JZ 0043 0054 A

2, 6, 8

146E-3623-4P00

24 VAC

J t/c

110 to 130°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HZ 0110 0130 A

2, 6, 8

146E-3623-4P00

24 VAC

J t/c

43 to 54°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JZ 0043 0054 A

2, 6, 8

146E-3623-4S00

24 VAC

J t/c

110 to 130°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HZ 0110 0130 A

2, 6, 8

146E-3623-4S00

24 VAC

J t/c

43 to 54°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JZ 0043 0054 A

2, 6, 8

146E-3625-1000

24 VAC

J t/c

250 to 430°F

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6HU 0250 0430 A

6, 8

146E-3625-1000

24 VAC

J t/c

121 to 221°C

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6JU 0121 0221 A

6, 8

146E-3625-1N00

24 VAC

J t/c

250 to 430°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HU 0250 0430 A

2, 6, 8

146E-3625-1N00

24 VAC

J t/c

121 to 221°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JU 0121 0221 A

2, 6, 8

146E-3625-1P00

24 VAC

J t/c

250 to 430°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HU 0250 0430 A

2, 6, 8

146E-3625-1P00

24 VAC

J t/c

121 to 221°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JU 0121 0221 A

2, 6, 8

146E-3625-1S00

24 VAC

J t/c

250 to 430°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HU 0250 0430 A

2, 6, 8

146E-3625-1S00

24 VAC

J t/c

121 to 221°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JU 0121 0221 A

2, 6, 8

146E-3625-2000

24 VAC

J t/c

250 to 430°F

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6HY 0250 0430 A

6, 8

146E-3625-2000

24 VAC

J t/c

121 to 221°C

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6JY 0121 0221 A

6, 8

146E-3625-2N00

24 VAC

J t/c

250 to 430°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HY 0250 0430 A

2, 6, 8

146E-3625-2N00

24 VAC

J t/c

121 to 221°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JY 0121 0221 A

2, 6, 8

146E-3625-2P00

24 VAC

J t/c

250 to 430°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HY 0250 0430 A

2, 6, 8

146E-3625-2P00

24 VAC

J t/c

121 to 221°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JY 0121 0221 A

2, 6, 8

146E-3625-2S00

24 VAC

J t/c

250 to 430°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HY 0250 0430 A

2, 6, 8

146E-3625-2S00

24 VAC

J t/c

121 to 221°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JY 0121 0221 A

2, 6, 8

146E-3625-3000

24 VAC

J t/c

250 to 430°F

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6HW 0250 0430 A

6, 8

146E-3625-3000

24 VAC

J t/c

121 to 221°C

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6JW 0121 0221 A

6, 8

146E-3625-3N00

24 VAC

J t/c

250 to 430°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HW 0250 0430 A

2, 6, 8

Watlow Controls

3/30/2005