Series 146 – Watlow Series 146 Retrofit User Manual

Page 32

Advertising
background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146D-3K2D-1200

24 VAC

K t/c

60 to 300°F

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5KU 0060 0300 A

2, 6, 8

146D-3K2D-1200

24 VAC

K t/c

16 to 149°C

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5LU 0016 0149 A

2, 6, 8

146D-3K2D-2100

24 VAC

K t/c

60 to 300°F

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6KY 0060 0300 A

6, 8

146D-3K2D-2100

24 VAC

K t/c

16 to 149°C

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6LY 0016 0149 A

6, 8

146D-3K2D-2200

24 VAC

K t/c

60 to 300°F

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5KY 0060 0300 A

2, 6, 8

146D-3K2D-2200

24 VAC

K t/c

16 to 149°C

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5LY 0016 0149 A

2, 6, 8

146D-3K2D-3100

24 VAC

K t/c

60 to 300°F

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6KW 0060 0300 A

6, 8

146D-3K2D-3100

24 VAC

K t/c

16 to 149°C

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6LW 0016 0149 A

6, 8

146D-3K2D-3200

24 VAC

K t/c

60 to 300°F

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5KW 0060 0300 A

2, 6, 8

146D-3K2D-3200

24 VAC

K t/c

16 to 149°C

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5LW 0016 0149 A

2, 6, 8

146D-3K2D-4100

24 VAC

K t/c

60 to 300°F

Low Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6KZ 0060 0300 A

6, 8

146D-3K2D-4100

24 VAC

K t/c

16 to 149°C

Low Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6LZ 0016 0149 A

6, 8

146D-3K2D-4200

24 VAC

K t/c

60 to 300°F

Low Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5KZ 0060 0300 A

2, 6, 8

146D-3K2D-4200

24 VAC

K t/c

16 to 149°C

Low Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5LZ 0016 0149 A

2, 6, 8

146D-3K2F-1100

24 VAC

K t/c

60 to 300°F

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6KU 0060 0300 A

6

146D-3K2F-1200

24 VAC

K t/c

60 to 300°F

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5KU 0060 0300 A

2, 6

146D-3K2F-2100

24 VAC

K t/c

60 to 300°F

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6KY 0060 0300 A

6

146D-3K2F-2200

24 VAC

K t/c

60 to 300°F

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5KY 0060 0300 A

2, 6

146D-3K2F-3100

24 VAC

K t/c

60 to 300°F

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6KW 0060 0300 A

6

146D-3K2F-3200

24 VAC

K t/c

60 to 300°F

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5KW 0060 0300 A

2, 6

146D-3K2F-4100

24 VAC

K t/c

60 to 300°F

Low Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6KZ 0060 0300 A

6

146D-3K2F-4200

24 VAC

K t/c

60 to 300°F

Low Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5KZ 0060 0300 A

2, 6

146D-3K3C-1100

24 VAC

K t/c

0 to 600°C

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6LU 0000 0600 A

6

146D-3K3C-1200

24 VAC

K t/c

0 to 600°C

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5LU 0000 0600 A

2, 6

146D-3K3C-2100

24 VAC

K t/c

0 to 600°C

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6LY 0000 0600 A

6

146D-3K3C-2200

24 VAC

K t/c

0 to 600°C

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5LY 0000 0600 A

2, 6

146D-3K3C-3100

24 VAC

K t/c

0 to 600°C

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6LW 0000 0600 A

6

146D-3K3C-3200

24 VAC

K t/c

0 to 600°C

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5LW 0000 0600 A

2, 6

146D-3K3C-4100

24 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6LZ 0000 0600 A

6

146D-3K3C-4200

24 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5LZ 0000 0600 A

2, 6

146D-3K3D-1100

24 VAC

K t/c

32 to 1112°F

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6KU 0032 1112 A

6, 8

146D-3K3D-1100

24 VAC

K t/c

0 to 600°C

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6LU 0000 0600 A

6, 8

146D-3K3D-1200

24 VAC

K t/c

32 to 1112°F

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5KU 0032 1112 A

2, 6, 8

146D-3K3D-1200

24 VAC

K t/c

0 to 600°C

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5LU 0000 0600 A

2, 6, 8

146D-3K3D-2100

24 VAC

K t/c

32 to 1112°F

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6KY 0032 1112 A

6, 8

146D-3K3D-2100

24 VAC

K t/c

0 to 600°C

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6LY 0000 0600 A

6, 8

146D-3K3D-2200

24 VAC

K t/c

32 to 1112°F

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5KY 0032 1112 A

2, 6, 8

146D-3K3D-2200

24 VAC

K t/c

0 to 600°C

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5LY 0000 0600 A

2, 6, 8

146D-3K3D-3100

24 VAC

K t/c

32 to 1112°F

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6KW 0032 1112 A

6, 8

146D-3K3D-3100

24 VAC

K t/c

0 to 600°C

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6LW 0000 0600 A

6, 8

146D-3K3D-3200

24 VAC

K t/c

32 to 1112°F

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5KW 0032 1112 A

2, 6, 8

Watlow Controls

3/30/2005

Page 27

Advertising