Brocade FastIron SX, FCX, and ICX Diagnostic Reference User Manual

Page 198

Advertising
background image

186

Brocade FastIron SX, FCX, and ICX Diagnostic Reference

53-1003076-02

show tech-support

9

Registers information

Possible stack trace

Active stack (if applicable)

Last packet (Application Data)

Possible data structure

MCT cluster details

License details

The following example shows the truncated output of the show tech-support command.

Brocade# show tech-support

Current configuration:

!

ver 07.4.00b1T7f3

!

stack unit 1

module 1 fcx-48-poe-port-management-module

module 2 fcx-cx4-2-port-16g-module

!

!

enable snmp config-tacacs

hostname FxRouter

ip route 0.0.0.0 0.0.0.0 172.26.64.1

!

logging console

username brocade password .....

tacacs-server host 172.26.50.95 auth-port 49 default key 1 $d=

tacacs-server host 172.26.50.94 auth-port 49 default key 1 $bn^^s

tacacs-server host 172.26.50.93 auth-port 49 default key 1 $r=?!\!

tacacs-server host ipv6 :: auth-port 49 default key 1 $!66i

tacacs-server key 1 $!66i

snmp-server community ..... ro

snmp-server community ..... rw

snmp-server community ..... rw

interface management 1

ip address 172.26.67.52 255.255.240.0

!

!

!

end

Copyright (c) 1996-2011 Brocade Communications Systems, Inc.

UNIT 1: compiled on Dec 20 2011 at 08:58:01 labeled as FCXR07400b1

(7155950 bytes) from Secondary FCXR07400b1.bin

SW: Version 07.4.00b1T7f3

Boot-Monitor Image size = 369369, Version:07.3.00T7f5 (grz07300b1)

HW: Stackable FCX648S-HPOE-PREM (PROM-TYPE FCX-ADV-U)

==========================================================================

UNIT 1: SL 1: FCX-48GS POE 48-port Management Module

Serial #: BCYXXXXXXXX

License: FCX_ADV_ROUTER_SOFT_PACKAGE (LID: deaHHJIhFJv)

P-ENGINE 0: type DB90, rev 01

P-ENGINE 1: type DB90, rev 01

PROM-TYPE: FCX-ADV-U

==========================================================================

UNIT 1: SL 2: FCX-2XGC 2-port 16G Module (2-CX4)

Advertising