Brocade FastIron SX, FCX, and ICX Diagnostic Reference User Manual

Page 46

Advertising
background image

34

Brocade FastIron SX, FCX, and ICX Diagnostic Reference

53-1003076-02

MCT debug commands

3

Brocade# debug cluster mdup

CLUSTER MDUP: Send Vlan mask message to peer

CLUSTER MDUP: Received vlan mask from peer for cluster 1

mdupmgr_proc_port_oper_status_change(port_id=3/13, oper_status=up, vlan=100 ) ->

mdupmgr_proc_port_oper_status_change(port_id=3/13, oper_status=up, vlan=100 ),

port is CCEP

mdupmgr_proc_port_oper_status_change(port_id=3/13, oper_status=up, vlan=100 ),

port is CCEP -> macmgr_move_mct_mac_from_icl_to_ccep

CLUSTER MDUP: Moving MACs from ICL port to CCEP port 3/13 for client 2668 in VLAN

100

mdupmgr_proc_port_oper_status_change(port_id=3/13, oper_status=up, vlan=100 )

DONE

mdupmgr_proc_port_oper_status_change(port_id=4/17, oper_status=up, vlan=100 ) ->

mdupmgr_proc_port_oper_status_change(port_id=4/17, oper_status=up, vlan=100 ),

port is CCEP

mdupmgr_proc_port_oper_status_change(port_id=4/17, oper_status=up, vlan=100 ),

port is CCEP -> macmgr_move_mct_mac_from_icl_to_ccep

CLUSTER MDUP: Moving MACs from ICL port to CCEP port 4/17 for client 3318 in VLAN

100

mdupmgr_proc_port_oper_status_change(port_id=4/17, oper_status=up, vlan=100 )

DONE

<<<<< mdupmgr_sync_static_mac_table >>>

mdupmgr_sync_static_mac_table done, sync 0 entries

mdupmgr_sync_mac_table(restart=yes,ccp_up_restart=yes)(T=95629)

mac_mdup_sync_in_progress=0, start_mac_index=0, previous_loop_start_mac_index=0,

g_mac_mdup_sync_delay=0

mdupmgr_sync_mac_table(restart=yes,ccp_up_restart=yes)(T=95629) DELAY SYNC

(mac_mdup_sync_in_progress=1, start_mac_index=0, previous_loop_start_mac_index=0,

g_mac_mdup_sync_delay=2)&

CLUSTER MDUP: Convert CCR to CCL for cluster_id: 1, client rbridge id = 2668

macmgr_convert_ccr_to_ccl(cluster_id=1, port_id=3/13)(T=95629) client

A-satya-000000c74d40 (hw_timer_gone=1 msec)&

CLUSTER MDUP: Convert CCR to CCL for cluster_id: 1, client rbridge id = 3318

macmgr_convert_ccr_to_ccl(cluster_id=1, port_id=4/17)(T=95629) client

A-satya-000000147d80 (hw_timer_gone=1 msec)&

mdupmgr_sync_mac_table(restart=no,ccp_up_restart=no)(T=95630)

mac_mdup_sync_in_progress=1, start_mac_index=0, previous_loop_start_mac_index=0,

g_mac_mdup_sync_delay=2

mdupmgr_sync_mac_table(restart=no,ccp_up_restart=no)(T=95630) DELAY SYNC

(mac_mdup_sync_in_progress=1, start_mac_index=0, previous_loop_start_mac_index=0,

g_mac_mdup_sync_delay=3)&

mdupmgr_sync_mac_table(restart=no,ccp_up_restart=no)(T=95631)

mac_mdup_sync_in_progress=1, start_mac_index=0, previous_loop_start_mac_index=0,

g_mac_mdup_sync_delay=3

mdupmgr_sync_mac_table(restart=no,ccp_up_restart=no)(T=95631) DELAY SYNC

(mac_mdup_sync_in_progress=1, start_mac_index=0, previous_loop_start_mac_index=0,

g_mac_mdup_sync_delay=4)&

debug cluster show

Syntax: [no] debug cluster show

This command displays debug flags for the cluster as shown in the following example.

Brocade# debug cluster show

CLUSTER debugging is :ENABLED

CLUSTER ALL debugging is :OFF

CLUSTER IPC debugging is :OFF

CLUSTER Hardware debugging is :OFF

Advertising