13. With continuity measurement selected, the instrument

goes on by opening the short-circuit and carrying out the
test between terminals E and C.

14. The value of resistance in the continuity test is shown in

field “Rpe” and the message “OK” appears in case the
result of the test is positive (measured value lower than
the maximum limit value set on the instrument).

15. The message “Outcome:OK” is finally shown by the

instrument in case the result of all performed tests is
positive.

15/05/12 15:34:26

M o d u l e :

S U N P W R 3 1 8

V d c :

5 4 8 . 0

V

I r r

:

0 W / m 2

T c :

A u t o

° C

V o c , I s c :

O K

R i ( 1 0 0 0 V ) 1 1 6 M

 O K

R p e ( C a l )

2 . 0 0

 O K

Outcome: OK

I V C K

16. Press the arrow key

 to show the following page in

which the values of parameters Voc and Isc are shown.
It shows:
 The module being used
 The average values of Voc and Isc under OPC

conditions

 The values of Voc and Isc measured under OPC and

the relevant partial results obtained by comparison with
the average values.

In general:

15/05/12 15:34:26

M o d u l e : S U N P W R 2 1 0
I r r

- - - W / m 2

T c ( A U T O )

- - ° C

V o c A v g @ O P C

6 4 7

V

I s c A v g @ O P C

5 . 4 3

A

V o c @ O P C

6 4 7

V O K

I s c @ O P C

5 . 3 5

A O K

V o c @ S T C - - - V
I s c @ S T C - - - A

Outcome: OK

I V C K

4%

Isc

Tol

100

se

4%

Voc

Tol

100

se

@

@

@

@

@

@

@

@

OPC

OPC

OPC

OPC

OPC

OPC

OPC

OPC

IscAvg

Isc

IscAvg

OK

Isc

Esito

VocAvg

Voc

VocAvg

OK

Voc

Esito

 The overall value of the results:

o

OK: if all results under OPC are OK,

o

NO if one of the results under OPC is NO

17. Press the

 key to go back to the previous screen.

18. Press the SAVE key to store the test result in the instrument’s memory (see § 7.2) or

the ESC/MENU key to exit the screen without saving and go back to the main
measuring screen.

CAUTION

The average values of Voc and Isc are displayed in the results’ page. These
values include the average values of Voc and Isc under OPC conditions
calculated as mean of the last 10 tests previously saved. If the user has carried
out and saved a number of tests <10 or reset the average values (see § 6.3.4)
the average value displayed during test N+1 will be calculated on the available
N values.